C613-50186-01 Rev B
Command Reference for AR2050V
1149
AlliedWare Plus™ Operating System - Version 5.4.7-1.x
BGP
AND
BGP4+ C
OMMANDS
BGP
SCAN
-
TIME
(BGP
ONLY
)
bgp scan-time (BGP only)
Overview
Use this command to set the interval for BGP route next-hop scanning.
Use the
no
variant of this command to disable this function.
Syntax
bgp scan-time <
time
>
no bgp scan-time [
<time
>]
Default
The default scanning interval is 60 seconds.
Mode
Router Configuration
Usage
Use this command to configure scanning intervals of BGP routers. This interval is
the period after which router checks the validity of the routes in its database.
To disable BGP scanning, set the scan time interval to 0 seconds.
Example
awplus#
configure terminal
awplus(config)#
router bgp 100
awplus(config-router)#
bgp scan-time 10
Parameter
Description
<time>
<0-60>
Scanning interval in seconds.