Rockwell Automation Publication 2198-UM004A-EN-P - October 2019
375
Chapter
13
Kinetix 5100 Safe Torque Off (STO) Feature
The 2198-E
xxxx
-ERS servo drives are equipped for hardwired Safe Torque Off
(STO). The hardwired STO function meets the requirements of Performance
Level d (PLd) and safety category 3 (CAT 3) per ISO 13849-1 and SIL 2 per
IEC 61508, IEC 61800-5-2 and IEC 62061.
The 2198-E
xxxx
-ERS servo drives use the STO connector for wiring external
safety devices and cascading hardwired safety connections from one drive to
another.
Certification
The TÜV Rheinland group has approved 2198-E
xxxx
-ERS servo drives with
hardwired safe torque-off for use in safety-related applications up to
ISO 13849-1, Performance Level d (PL d) and Category 3, SIL CL 2 per
IEC 61508, IEC 61800-5-2, and IEC 62061, in which removing the motion
producing power is considered to be the safe state.
For product certifications currently available from Rockwell Automation, go to
.
Topic
Page
Average Frequency of a Dangerous Failure per Hour
Safe Torque Off Connector Data
Wire the Safe Torque Off Circuit
Safe Torque Off Specifications
Содержание Kinetix 5100 2198-E1004-ERS
Страница 114: ...114 Rockwell Automation Publication 2198 UM004A EN P October 2019 Chapter 6 Set Up EtherNet IP Communication Notes ...
Страница 402: ...402 Rockwell Automation Publication 2198 UM004A EN P October 2019 Chapter 14 Absolute Position Recovery Notes ...
Страница 484: ...484 Rockwell Automation Publication 2198 UM004A EN P October 2019 Appendix C Use Add On Instructions Notes ...
Страница 488: ...488 Rockwell Automation Publication 2198 UM004A EN P October 2019 Appendix D Full Closed Loop Control Notes ...
Страница 499: ......