Rockwell Automation Publication 2198-UM004A-EN-P - October 2019
99
Use the Keypad Interface
Chapter 5
Drive Status Display
This display provides drive information and access to the Setting display, which
shows network and parameter information. When the drive is enabled/servo on,
the information can only be viewed.
Use the keys to move between status information displays.
24
Monitor variable number 2 displays the content of
parameter ID664 (P0.010). Specify the monitor variable
code by using ID669 (P0.018).
—
25
Monitor variable number 3 displays the content of
parameter ID665 (P0.011). Specify the monitoring
variable code by using ID670 (P0.019).
—
26
Monitor variable number 4 displays the content of
parameter ID666 (P0.012). Specify the monitoring
variable code by using ID667 (P0.020).
—
27
Offset value between motor position and Z phase in PUU
unit. The value is 0 when the position overlaps with Z
phase. The greater the value, the greater the offset.
User Unit
28
Current drive fault.
—
Table 59 - Real Time Display Symbols (Continued)
Code
Real Time Displayed
Symbol
Description
Unit
Drive
Status
Device
Information
Version
Information
Setting
Information Display/Setup Mode
Содержание Kinetix 5100 2198-E1004-ERS
Страница 114: ...114 Rockwell Automation Publication 2198 UM004A EN P October 2019 Chapter 6 Set Up EtherNet IP Communication Notes ...
Страница 402: ...402 Rockwell Automation Publication 2198 UM004A EN P October 2019 Chapter 14 Absolute Position Recovery Notes ...
Страница 484: ...484 Rockwell Automation Publication 2198 UM004A EN P October 2019 Appendix C Use Add On Instructions Notes ...
Страница 488: ...488 Rockwell Automation Publication 2198 UM004A EN P October 2019 Appendix D Full Closed Loop Control Notes ...
Страница 499: ......