Chapter 12
Motion Control Applications
Data Array
Data array can store up to 800 data (0…799) with each data size of 32-bit. It can
be used to store the high-speed captured data and high-speed compared data as
well as E-Cam curves. Users have to segment the space for these three functions as
their individual spaces are not restricted in the default setting. This way data
being overwritten or changed incorrectly can be avoided. You can set ID193
(P2.008) to 30 and then 35 or use the KNX5100C configuration software to
write the data to EEPROM, otherwise, the data does not remain after power off.
A user-friendly setting screen is also provided in the configuration software for
reading / writing the data array. See
.
With two channels provided, users can use panel, communication, or the
configuration software to read data from or write data to the data array. Channel
1 can be set by ID304 (P5.011), ID305 (P5.012), and ID306 (P5.013).
ID304 (P5.011) specifies the address for reading / writing of data array. ID305
(P5.012), and ID306 (P5.013) are the windows of reading / writing. Both can be
used to read / write, but the behaviors after reading / writing differ. See
. Channel 2 can be set by ID304 (P5.011), ID388…ID391
(P5.100
…
103).
ID304 (P5.011) sets the address for reading / writing of data array. ID388
(P5.100) can read data from or write data to the data array address following the
address set by ID304 (P5.011). ID305 (P5.012), and ID391 (P5.103) work the
same way. If the address number has reached the max. 799, then the address
remains 799 instead of adding up. You can find more details in
Example: When using the drive panel or communication for reading from or
writing to the data array, add values to the data array address in this order:
• Data array #11 = 100,
• Data array #12 = 200,
• Data array #13 = 300.
Table 106 - Channel 1 - Reading or Writing of Data Array
Parameter
Description
ID304 (P5.011) Address
of reading / writing
Specify the address for reading from or writing to the data array
Window for reading or
writing
Configured by
Behavior after reading
Behavior after writing
ID305 (P5.012)
Window #1 for reading
or writing
Panel
Value of ID304 (P5.011) does not
add 1
Value of ID304 (P5.011)
adds 1
Communication or
configuration software
Value of ID304 (P5.011) adds 1
Value of ID304 (P5.011)
adds 1
ID306 (P5.013)
Window #2 for reading
or writing
Panel
Value of ID304 (P5.011) adds 1
Cannot be written via drive
panel
Communication or
configuration software
Value of ID304 (P5.011) adds 1
Value of ID304 (P5.011)
adds 1
Содержание Kinetix 5100 2198-E1004-ERS
Страница 114: ...114 Rockwell Automation Publication 2198 UM004A EN P October 2019 Chapter 6 Set Up EtherNet IP Communication Notes ...
Страница 402: ...402 Rockwell Automation Publication 2198 UM004A EN P October 2019 Chapter 14 Absolute Position Recovery Notes ...
Страница 484: ...484 Rockwell Automation Publication 2198 UM004A EN P October 2019 Appendix C Use Add On Instructions Notes ...
Страница 488: ...488 Rockwell Automation Publication 2198 UM004A EN P October 2019 Appendix D Full Closed Loop Control Notes ...
Страница 499: ......