Rockwell Automation Publication 2198-UM004A-EN-P - October 2019
277
Motion Control in PR Mode
Chapter 11
options of forward (always runs forward), backward (always runs backward), and
shortest distance. S_LOW is the speed unit with available options of 0.1 rpm or
0.01 rpm. The option AUTO automatically loads the next PR command. When
current PR command completes, the next PR command will be auto-executed.
ACC / DEC is the acceleration / deceleration time setting determined by shared
PR parameters ID312…ID327(P5.020… P5.035). SPD is the target speed set by
the PR shared parameters ID352…ID367 (P5.060…P5.075). DLY is the delay
time. When motor reaches the target position, the servo drive will start counting
the delay time. Position command is the target position of each index segment.
Figure 106 - PR Mode Index Position Screen
Below are the functions of each bit when a index command is applied using the
ID339…ID595 (P6.002…P7.098) PRCmd
X
Setting.
PR parameters
D
C
B
A
U
Z
Y
X
Command type
-
OPT2
DLY
SPD
DEC
ACC
OPT
0xA
Data content
Index Position command [PUU](0 – P2.052-1)
Содержание Kinetix 5100 2198-E1004-ERS
Страница 114: ...114 Rockwell Automation Publication 2198 UM004A EN P October 2019 Chapter 6 Set Up EtherNet IP Communication Notes ...
Страница 402: ...402 Rockwell Automation Publication 2198 UM004A EN P October 2019 Chapter 14 Absolute Position Recovery Notes ...
Страница 484: ...484 Rockwell Automation Publication 2198 UM004A EN P October 2019 Appendix C Use Add On Instructions Notes ...
Страница 488: ...488 Rockwell Automation Publication 2198 UM004A EN P October 2019 Appendix D Full Closed Loop Control Notes ...
Страница 499: ......