Appendix C
Use Add-On Instructions
Operands
Description
The raC_Dvc_K5100_MSF instruction directly and immediately turns off drive
output and disables the servo loop on any physical servo axis. The resulting state
of the axis is referred to as Ref_Axis.Input.Active.
In this transitional instruction, the relay ladder, toggle the Rung-condition-in
from cleared to set each time that the instruction executes.
Execution
Error Codes
• 100 - Kinetix 5100 drive is not ready
• 101 - Kinetix 5100 drive is faulted
• 104 - Another raC_Dvc_K5100_MSF message is executing
• 129 - Motor not connected
See
Operand
Type
Format
Description
Instance
raC_Dvc_K5100_MSF
Tag
Instance of raC_Dvc_K5100_MSF
Ref_Axis
raC_UDT_Dvc_K5100_Assm
Tag
Name of the axis to perform operation on
Mnemonic
Description
Sts_EN (Enable)
This bit is set when the rung makes a false-to-true transition and remains set until the servo
message transaction is completed and the rung goes false.
Sts_DN (Done)
This bit is set when the axis servo action has been successfully disabled and the drive enable bit
have been cleared.
Sts_ER (Error)
This bit is set to indicate that the instruction detected an error.
IMPORTANT
The instruction execution can take multiple scans to execute because it requires
multiple course updates to complete the request. The Done (Sts_DN) bit is not
set immediately, but only after the request is completed.
Condition
Ladder Diagram Action
Prescan
The Sts_EN, Sts_DN, Sts_ER and
Ref_Axis.Output_IO.ServoOff bits are cleared. The rung-
condition-out is set to false.
Rung-condition-in is false
The Sts_EN bit is cleared if the Sts_DN or Sts_ER bit is
true.
Rung-condition-in is true
The Sts_EN bit is cleared to false if the Sts_DN or Sts_ER
bit is true.
Postscan
—
Содержание Kinetix 5100 2198-E1004-ERS
Страница 114: ...114 Rockwell Automation Publication 2198 UM004A EN P October 2019 Chapter 6 Set Up EtherNet IP Communication Notes ...
Страница 402: ...402 Rockwell Automation Publication 2198 UM004A EN P October 2019 Chapter 14 Absolute Position Recovery Notes ...
Страница 484: ...484 Rockwell Automation Publication 2198 UM004A EN P October 2019 Appendix C Use Add On Instructions Notes ...
Страница 488: ...488 Rockwell Automation Publication 2198 UM004A EN P October 2019 Appendix D Full Closed Loop Control Notes ...
Страница 499: ......