52
Rockwell Automation Publication 2198-UM004A-EN-P - October 2019
Chapter 3
Connector Data and Feature Descriptions
Wiring and Signal Specifications
The digital outputs are optically isolated and sink up to 24V DC. Electrical
Figure 27 - Digital Output Circuitry
Table 29 - Digital Output Signal Specifications
OUTPUT
x–
OUTPUT
x+
24V DC
R
OUTPUT
x–
OUTPUT
x+
24V DC
In this example, the drive applies the external
24V DC power supply to a resistive load.
In this example, the drive applies the external
24V DC power supply to an inductive load.
Servo Drive
Servo Drive
Parameter
Description
Min
Max
ON state current
Current flow when the output transistor is ON
–
40 mA
OFF state current
Current flow when the output transistor is OFF
–
0.1 mA
ON state voltage
Voltage across the output transistor when ON
–
1.5V @ 40 mA
OFF state voltage
Voltage across the output transistor when OFF
–
30V
Scan time
Interval of the digital outputs status updating in
drive firmware
–
250 µs
Pass through delay
Signal propagation delay from the firmware-
accessible registers to the digital output
–
1.0 ms
Содержание Kinetix 5100 2198-E1004-ERS
Страница 114: ...114 Rockwell Automation Publication 2198 UM004A EN P October 2019 Chapter 6 Set Up EtherNet IP Communication Notes ...
Страница 402: ...402 Rockwell Automation Publication 2198 UM004A EN P October 2019 Chapter 14 Absolute Position Recovery Notes ...
Страница 484: ...484 Rockwell Automation Publication 2198 UM004A EN P October 2019 Appendix C Use Add On Instructions Notes ...
Страница 488: ...488 Rockwell Automation Publication 2198 UM004A EN P October 2019 Appendix D Full Closed Loop Control Notes ...
Страница 499: ......