Rockwell Automation Publication 2198-UM004A-EN-P - October 2019
479
Use Add-On Instructions
Appendix C
Operands
Operand
Type
Format
Description
Instance
raC_Dvc_K5100_MAH Tag
Instance of raC_Dvc_K5100_MAH
Ref_Axis
raC_UDT_Dvc_K5100
_Assm
Tag
Name of the axis to perform operation on
Cfg_
HomingMethod
SINT
Tag
0 - Homing in forward direction and regard PL as homing origin, Return to Z pulse.
1 - Homing in forward direction and regard PL as homing origin, Go forward to Z pulse.
2 - Homing in forward direction and regard PL as homing origin, Do not look for Z pulse.
3 - Homing in reverse direction and regard NL as homing origin, Return to Z pulse.
4 - Homing in reverse direction and regard NL as homing origin, Go forward to Z pulse.
5 - Homing in reverse direction and regard NL as homing origin, Do not look for Z pulse.
6 - Homing in forward direction, ORG: OFF to ON as homing origin, Return to Z pulse, Shows error when encounter
limit.
7 - Homing in forward direction, ORG: OFF to ON as homing origin, Return to Z pulse, Reverse direction when
encounter limit.
8 - Homing in forward direction, ORG: OFF to ON as homing origin, Go forward to Z pulse, Shows error when
encounter limit.
9 - Homing in forward direction, ORG: OFF to ON as homing origin, Go forward to Z pulse, Reverse direction when
encounter limit.
10 - Homing in forward direction, ORG: OFF to ON as homing origin, Do not look for Z pulse, Shows error when
encounter limit.
11 - Homing in forward direction, ORG: OFF to ON as homing origin, Do not look for Z pulse, Reverse direction when
encounter limit.
12 - Homing in reverse direction, ORG: OFF to ON as homing origin, Return to Z pulse, Shows error when encounter
limit.
13 - Homing in reverse direction, ORG: OFF to ON as homing origin, Return to Z pulse, Reverse direction when
encounter limit.
14 - Homing in reverse direction, ORG: OFF to ON as homing origin, Go forward to Z pulse, Shows error when
encounter limit.
15 - Homing in reverse direction, ORG: OFF to ON as homing origin, Go forward to Z pulse, Reverse direction when
encounter limit.
16 - Homing in reverse direction, ORG: OFF to ON as homing origin, Do not look for Z pulse, Shows error when
encounter limit.
17 - Homing in reverse direction, ORG: OFF to ON as homing origin, Do not look for Z pulse, Reverse direction when
encounter limit.
Содержание Kinetix 5100 2198-E1004-ERS
Страница 114: ...114 Rockwell Automation Publication 2198 UM004A EN P October 2019 Chapter 6 Set Up EtherNet IP Communication Notes ...
Страница 402: ...402 Rockwell Automation Publication 2198 UM004A EN P October 2019 Chapter 14 Absolute Position Recovery Notes ...
Страница 484: ...484 Rockwell Automation Publication 2198 UM004A EN P October 2019 Appendix C Use Add On Instructions Notes ...
Страница 488: ...488 Rockwell Automation Publication 2198 UM004A EN P October 2019 Appendix D Full Closed Loop Control Notes ...
Страница 499: ......