250
Rockwell Automation Publication 2198-UM004A-EN-P - October 2019
Chapter 11
Motion Control in PR Mode
Definitions are as follows:
• YX
TYPE command type: when executing 1…3, it can be interrupted and
stopped by DI.STP and software limits.
• UZ
Y: OPT, Option
X: TYPE, Command Type
Bit 3
Bit 2
Bit 1
Bit 0
-
UNIT
AUTO
INS
1: Constant speed control
CMD
OVLP
INS
2: Point-to-point command
3: Point-to-point command (Proceed to the next command when completed)
-
-
-
INS
7: Jump to the specified PR command
-
ROM
AUTO
INS
8: Write to parameter or Data Array
DIR
OVLP
INS
A: Index position control
-
-
-
-
B: Statement / arithmetic operation
U: DEC, Deceleration Time
Z: ACC, Acceleration Time Corresponding Parameter
Default Value (ms)
0
0
ID312 (P5.020)
200
1
1
ID313 (P5.021)
300
2
2
ID314 (P5.022)
500
3
3
ID315 (P5.023)
600
4
4
ID316 (P5.024)
800
5
5
ID317 (P5.025)
900
6
6
ID318 (P5.026)
1000
7
7
ID319 (P5.027)
1200
8
8
ID320 (P5.028)
1500
9
9
ID321 (P5.029)
2000
10
10
ID322 (P5.030)
2500
11
11
ID323 (P5.031)
3000
12
12
ID324 (P5.032)
5000
13
13
ID325 (P5.033)
8000
14
14
ID326 (P5.034)
50
15
15
ID327 (P5.035)
30
Содержание Kinetix 5100 2198-E1004-ERS
Страница 114: ...114 Rockwell Automation Publication 2198 UM004A EN P October 2019 Chapter 6 Set Up EtherNet IP Communication Notes ...
Страница 402: ...402 Rockwell Automation Publication 2198 UM004A EN P October 2019 Chapter 14 Absolute Position Recovery Notes ...
Страница 484: ...484 Rockwell Automation Publication 2198 UM004A EN P October 2019 Appendix C Use Add On Instructions Notes ...
Страница 488: ...488 Rockwell Automation Publication 2198 UM004A EN P October 2019 Appendix D Full Closed Loop Control Notes ...
Страница 499: ......