Rockwell Automation Publication 2198-UM004A-EN-P - October 2019
283
Motion Control in PR Mode
Chapter 11
Each command type, except for (B) Arithmetic/Statement, let you configure the
Options and the Speed and Time Setting for the PR command. The options
differ depending on the command type. These settings correspond to the Y, A, U,
A, B, and C values of the PRCmd
X
Setting parameters, for example ID399
(P6.002) PRCmd1Setting.
See
PR Command Setting and Data Definitions on page 248
for more
information.
For (7) Jump to the specified PR command, you can configure a PR command
number to jump to. For (8) Write to Parameter or Data Array, you can configure
a Target parameter or data array and a Data Source. The data source can be any of
the following:
• 0: Constant
• 1: Parameter
• 2: Data Array
• 3: Monitor Variable
Figure 112 - PR Command Settings