Rockwell Automation Publication 2198-UM004A-EN-P - October 2019
243
Modes of Operation
Chapter 10
Additionally, users can enable or disable the limit function via the DI.TRQLM
signal, which is more flexible, but would need to occupy one DI setting. Torque
limit function can be enabled by either parameter ID118 (P1.002) or the digital
input (DI).
Apply Speed Limit
The maximum speed in each mode is determined by the internal parameter
ID160 (P1.055), no matter if it is in position, speed, or torque mode. The issuing
method of speed limit command and speed command is identical. The command
source can be the external analog voltage or internal parameters ID125…ID127
(P1.009…P1.011).
Speed limit is applicable only in torque mode (T) for controlling the motor’s
maximum speed. If using external analog voltage in torque mode, DI signals will
be available and can be set to SPD0…SPD1 for motor speed limit selection
(internal parameters). If not, users can use analog voltage input as the speed limit
command. When parameter ID118 (P1.002) is set to 1, the speed limit function
is enabled. See the following timing diagram.
To set the speed limit, see the following diagram.
Table 94 - Relevant Parameters
Parameter
Name
ID118 (P1.002)
VelocityTorqueLimitAction
ID125 (P1.009)
PresetVelocityCmd_Limit_1
ID126 (P1.010)
PresetVelocityCmd_Limit_2
ID127 (P1.011)
PresetVelocityCmd_Limit_3
ID160 (P1.055)
MaximumSpeed
Select by I/O Connector DI.SPD0, DI.SPD1 signal
Vref
(analog
command)
(0)
PresetVelocityCmd_Limit_1
ID125 (P1.009)
PresetVelocityCmd_Limit_2
ID126 (P1.010)
Speed Limit
Command
PresetVelocityCmd_Limit_3
ID127 (P1.011)
Содержание Kinetix 5100 2198-E1004-ERS
Страница 114: ...114 Rockwell Automation Publication 2198 UM004A EN P October 2019 Chapter 6 Set Up EtherNet IP Communication Notes ...
Страница 402: ...402 Rockwell Automation Publication 2198 UM004A EN P October 2019 Chapter 14 Absolute Position Recovery Notes ...
Страница 484: ...484 Rockwell Automation Publication 2198 UM004A EN P October 2019 Appendix C Use Add On Instructions Notes ...
Страница 488: ...488 Rockwell Automation Publication 2198 UM004A EN P October 2019 Appendix D Full Closed Loop Control Notes ...
Страница 499: ......