Rockwell Automation Publication 2198-UM004A-EN-P - October 2019
49
Connector Data and Feature Descriptions
Chapter 3
Table 24 - Digital Input Function Names
The digital input functions are defined in
Description of Digital Input Functions
. If the defined DI (Digital Input) function needs to change to meet
your application requirements, you can program the function of DI1…DI10 by
using the corresponding parameters listed in
.
Table 25 - DI Signal Parameters
Wiring and Signal Specifications
The digital inputs are optically isolated and sink up to 24V DC. Electrical details
. You can configure the inputs for PNP sourcing or NPN
sinking.
Value
Name
Description
0x02
ARST
Alarm Reset
0x04
CCLR
Pulse clear
0x08
CTRG
Command triggered
0x09
TRQLM
Torque limit
0x10
SPDLM
Speed limit enabled
0x11
POS0
Internal position command selection 1…99 Bit0
0x12
POS1
Internal position command selection 1…99 Bit1
0x14
SPD0
Internal speed command selection (1…4) Bit0
0x15
SPD1
Internal speed command selection (1…4) Bit1
0x16
TCM0
Internal speed torque selection (1…4) Bit0
0x17
TCM1
Internal speed torque selection (1…4) Bit1
0x18
S-P
Speed / Position mode switching
0x20
T-P
Torque / Position mode switching
0x21
EMGS
(1)
(1) The Emergency Stop (EMGS) function is a method of disabling the motor when active. It is not a safety rated input or related to
functional safety.
Emergency stop
0x22
NL(CWL)
Negative limit (overtravel)
0x23
PL(CCWL)
Positive limit (overtravel)
DI Signal
Pin
DI
x
Configuration
Parameter
DI Signal
Pin
DI
x
Configuration
Parameter
Standard DI
DI1
9
ID195 (P2.010)
Standard DI
DI6
32
ID200 (P2.015)
DI2
10
ID196 (P2.011)
DI7
31
ID201 (P2.016)
DI3
34
ID197 (P2.012)
DI8
34
ID202 (P2.017)
DI4
8
ID198 (P2.013)
DI9
29
ID220 (P2.036)
DI5
33
ID199 (P2.014)
DI10
38
ID221 (P2.037)
Содержание Kinetix 5100 2198-E1004-ERS
Страница 114: ...114 Rockwell Automation Publication 2198 UM004A EN P October 2019 Chapter 6 Set Up EtherNet IP Communication Notes ...
Страница 402: ...402 Rockwell Automation Publication 2198 UM004A EN P October 2019 Chapter 14 Absolute Position Recovery Notes ...
Страница 484: ...484 Rockwell Automation Publication 2198 UM004A EN P October 2019 Appendix C Use Add On Instructions Notes ...
Страница 488: ...488 Rockwell Automation Publication 2198 UM004A EN P October 2019 Appendix D Full Closed Loop Control Notes ...
Страница 499: ......