Rockwell Automation Publication 2198-UM004A-EN-P - October 2019
97
Use the Keypad Interface
Chapter 5
Figure 67 - Real Time Data Display
For example:
On the Real Time Display, the drive displays FB.PUU. When you press
, the
drive displays C-PUU, which is the input pulse number. See
description of the Real Time Display symbols.
For more information on parameter values and descriptions, see the
Knowledgebase article
, Kinetix 5100 Servo Drive Parameter Data and
Fault Codes.
Table 59 - Real Time Display Symbols
Code
Real Time Displayed
Symbol
Description
Unit
0
Motor feedback pulse number after the scaling of
electronic gear ratio.
User unit
1
Input pulse number of pulse command after the scaling of
electronic gear ratio.
User unit
2
The deviation between control command pulse and
feedback pulse number.
User unit
3
Motor feedback pulse number (encoder unit) (1.28 million
count/rev)
Count
4
Input pulse number of pulse command before the scaling
of electronic gear ratio. (encoder unit)
Count
Drive
Status
Real Time Data
Display Mode
P3
P2
P1
...
...
...
PN
Fault
Mode
Fault
Clear
Fault
Occurred
Drive Disable/
Servo O
ff
Drive Enable/
Servo On
Drive is Running
No key event/fault
Information Display/
Setup Mode
Содержание Kinetix 5100 2198-E1004-ERS
Страница 114: ...114 Rockwell Automation Publication 2198 UM004A EN P October 2019 Chapter 6 Set Up EtherNet IP Communication Notes ...
Страница 402: ...402 Rockwell Automation Publication 2198 UM004A EN P October 2019 Chapter 14 Absolute Position Recovery Notes ...
Страница 484: ...484 Rockwell Automation Publication 2198 UM004A EN P October 2019 Appendix C Use Add On Instructions Notes ...
Страница 488: ...488 Rockwell Automation Publication 2198 UM004A EN P October 2019 Appendix D Full Closed Loop Control Notes ...
Страница 499: ......