Rockwell Automation Publication 2198-UM004A-EN-P - October 2019
57
Connector Data and Feature Descriptions
Chapter 3
Figure 35 - Encoder OCA Output (open collector Z pulse output)
Ethernet Communication Specifications
The PORT1 and PORT2 (RJ45) Ethernet connectors provide communication
with the Logix 5000™ controller.
Table 32 - Ethernet Communication Specifications
24 V
48
13
30V (max),
50 mA
OCZMOUT
Analog GND
AGND
Servo Drive
I/O Connector with
2198-TBIO Expansion Block
Attribute
Value
Communication
The drive auto-negotiates Speed and Duplex modes. These modes
can be forced through the Logix Designer application. 100BASE-TX,
full-duplex is recommended for maximum performance.
Request Packet Interval (RPI)
2.0 ms, min
Auto MDI/MDIX crossover detection/correction
Yes
Cabling
CAT5e shielded, 100 m (328 ft), max