436
Rockwell Automation Publication 2198-UM004A-EN-P - October 2019
Appendix A
Interconnect Diagrams
Power Wiring Examples
You must supply input power components. The three-phase AC line filter is
wired as shown in
.
In this example, the 2198-E1004-ERS, 2198-E1007-ERS, 2198-E1015-ERS, and
2198-E1020-ERS drives are wired for 120V or 230V single-phase operation.
Figure 205 - Kinetix 5100 Drive (120V or 230V single-phase input power)
14
PE ground point is a mounting screw (see
Connect the Braided Ground Strap Example
).
15
For motor cable specifications, see the Kinetix Motion Accessories Technical Data, publication
.
16
MPL-A5
xx
, MPM-A165…MPM-A215, and MPF-A5
xx
encoders use the +9V DC supply.
17
TLP-A
xxx
, MPL-A15
xx
…MPL-A45
xx
, MPM-A115…MPM-A130, MPF-A3
xx
…MPF-A45
xx,
and MPS-A
xxx
encoders use the +5V DC supply.
18
Motor brake connector pins are labeled plus (+) and minus (-) or F and G, respectively. Motor power connector pins are labeled U, V, W, and GND or A, B, C, and D,
respectively.
Table 134 - Interconnect Diagram Notes (Continued)
Note
Information
L1
U
V
W
L2
L3
DC+
ISH
ESH
L1C
L2C
P1
P2
DC–
(SRDY+)
OUTPUT1– (SRDY–)
7
6
Single-phase AC Input
120V or 230V rms AC, 50/60 Hz
Bonded Cabinet
Ground Bus *
PE (mounting screw)
Note 14
Mains
AC Input Power
Connector
Circuit
Protection*
M1
Contactor*
Passive Shunt
Connector
Note 4
Motor Power
Connector
2198-E1004-ERS, 2198-E1007-ERS,
2198-E1015-ERS, and 2198-E1020-ERS
Kinetix 5100 Servo Drives
* Indicates User Supplied Component
See table on
for note information.
AC Line Filter
Note 6
Three-phase
Motor Power
Connections
Note 15
Ground Plate
Note 13
Internal Shunt
Resistor
Control Input Power
Connector
Note 2
Circuit
Protection*
I/O Connector with
2198-TBIO Expansion Block
Refer to
Attention
statement (Note 12).
STOP *
START *
CR1 *
CR1 *
CR1 *
M1 *
Customer Supplied
24V DC
Note 11
Содержание Kinetix 5100 2198-E1004-ERS
Страница 114: ...114 Rockwell Automation Publication 2198 UM004A EN P October 2019 Chapter 6 Set Up EtherNet IP Communication Notes ...
Страница 402: ...402 Rockwell Automation Publication 2198 UM004A EN P October 2019 Chapter 14 Absolute Position Recovery Notes ...
Страница 484: ...484 Rockwell Automation Publication 2198 UM004A EN P October 2019 Appendix C Use Add On Instructions Notes ...
Страница 488: ...488 Rockwell Automation Publication 2198 UM004A EN P October 2019 Appendix D Full Closed Loop Control Notes ...
Страница 499: ......