Parameters 443
DIO1
Digital input/output DIO1 (
, bit 0).
8
DIO2
Digital input/output DIO2 (
, bit 1).
9
ESP CW bit 12
Parameter
, bit-12 status controls
enable/disable status of the function.
10
). -
Defines time setting for periodic cleaning schedule.
When parameter
time counter
reaches the value set in this parameter, the cleaning request
is automatically generated.
After cleaning operation is completed, the timer is then reset
for another round with parameter
which displays remaining time till the next cleaning request
based on this parameter time setting.
Note:
For the time trigger to work, parameter
, bit-2 must be set to 1.
0.00
0.00...650.00 hour
Time trigger in hours.
100 = 1hour
Defines the desired quantity of cleaning cycles.
Each cycle consists of two speed steps with period of off-time
after each step. The period and dynamics of each cycle are
defined with parameters
...
.
1
0...65000
Number of cleaning cycles.
1 = 1
Defines speed reference for the first step of cleaning cycle.
Note that the parameter
setting is also
taken into use for the cleaning operation.
-10.00
-300.00...300.00 %
First step reference in percentage.
10 = 1%
Defines the time period for the first step of cleaning cycle.
5.0
0.0...6500.0 s
First step time in second.
10 = 1s
Defines the time period for the pause after each step.
The speed reference will be zero during Off time.
5.0
0.0...6500.0 s
Off time in seconds.
10 = 1s
Defines speed reference for the second step of cleaning
cycle.
Note that the parameter
setting is also
taken into use for the cleaning operation.
10.00
-300.00...300.00 %
Second step reference in percentage.
10 = 1%
Defines the time period for the second step of cleaning cycle. 5.0
0.0...6500.0 s
Second step time in seconds.
10 = 1s
Defines acceleration time for the cleaning operation.
20.00
0.00...30000.00 s
Cleaning acceleration time in seconds.
1 = 1s
Defines deceleration time for the cleaning operation.
20.00
0.00...30000.00 s
Cleaning deceleration time in seconds.
1 = 1s
Defines the motor current reference setting used during
acceleration period of every cleaning cycle.
This helps to produce higher starting torque and assist
acceleration.
Note:
For the Acceleration boost to work, parameter
, bit-7 must be set to 1.
100.00
0.00...300.00 %
Acceleration boost current.
10 = 1%
No.
Name/Value
Description
Def
/
FbEq16
Содержание ACS880-01 Series
Страница 1: ...ABB industrial drives Firmware manual ACS880 ESP control program option N5600 ...
Страница 4: ......
Страница 12: ...12 Table of contents ...
Страница 20: ...20 Introduction to the manual ...
Страница 22: ...22 Using the control panel ...
Страница 28: ...28 Control locations and operating modes ...
Страница 145: ...Application macros 145 Fieldbus control macro This application macro is not supported by the current firmware version ...
Страница 146: ...146 Application macros ...
Страница 502: ...502 Parameters ...
Страница 606: ...606 Fault tracing ...
Страница 662: ...662 Control chain diagrams ...
Страница 664: ...Contact us www abb com drives www abb com drivespartners 3AXD50000041193 Rev A EN EFFECTIVE 2017 06 30 ...