![ABB ACS880-01 Series Скачать руководство пользователя страница 444](http://html.mh-extra.com/html/abb/acs880-01-series/acs880-01-series_firmware-instructions_2621444.webp)
444 Parameters
Defines source for the cleaning abort command.
The cleaning operation can be interrupted at any time with
abort command. In such case, ESP control program will
immediately switch to production mode.
Not selected
Cleaning abort source is not selected.
0
Selected
Cleaning abort source is selected.
1
DI1
Digital input DI1 (
, bit 0).
2
DI2
Digital input DI2 (
, bit 1).
3
DI3
Digital input DI3 (
, bit 2).
4
DI4
Digital input DI4 (
, bit 3).
5
DI5
Digital input DI5 (
, bit 4).
6
DI6
Digital input DI6 (
, bit 5).
7
DIO1
Digital input/output DIO1 (
, bit 0).
8
DIO2
Digital input/output DIO2 (
, bit 1).
9
Source selection (see
). -
Defines the source for the supervision low signal.
The value from this parameter is then compared with the limit
set in parameter
. If the observed
signal is lower than the limit for the time period set in
parameter
, then cleaning
procedure is interrupted. The ESP control program will
immediately switch to production mode. The supervision low
is not active during off-time period.
Note:
For the supervision low function to work, parameter
bit-11 must be set to 1.
NULL
Zero
0
AI1 scaled
See parameter
1
AI2 scaled
See parameter
2
FBA1 ref
See parameter
(page
).
3
FBA2 ref
See parameter
(page
).
4
EFB1 ref
See parameter
(page
).
5
EFB2 ref
See parameter
(page
).
6
Estimated motor
current
Parameter
(see page
).
7
Motor current%
Estimated motor current in % of nominal motor current.
8
Source selection (see
). -
Defines low limit value for the Supervision low function.
See parameter
0.00
0.00...30000.00
Supervision low limit.
10 = 1
Defines delay time for the Supervision low function.
See parameter
10.0
0.0...3200.0 s
Supervision low delay.
10 = 1s
No.
Name/Value
Description
Def
/
FbEq16
Содержание ACS880-01 Series
Страница 1: ...ABB industrial drives Firmware manual ACS880 ESP control program option N5600 ...
Страница 4: ......
Страница 12: ...12 Table of contents ...
Страница 20: ...20 Introduction to the manual ...
Страница 22: ...22 Using the control panel ...
Страница 28: ...28 Control locations and operating modes ...
Страница 145: ...Application macros 145 Fieldbus control macro This application macro is not supported by the current firmware version ...
Страница 146: ...146 Application macros ...
Страница 502: ...502 Parameters ...
Страница 606: ...606 Fault tracing ...
Страница 662: ...662 Control chain diagrams ...
Страница 664: ...Contact us www abb com drives www abb com drivespartners 3AXD50000041193 Rev A EN EFFECTIVE 2017 06 30 ...