![ABB ACS880-01 Series Скачать руководство пользователя страница 495](http://html.mh-extra.com/html/abb/acs880-01-series/acs880-01-series_firmware-instructions_2621495.webp)
Parameters 495
Defines an angle offset between the zero position of the
synchronous motor and the zero position of the position
sensor.
This value is initially set by the autophasing routine when
parameter
, and can be fine-tuned later on.
Notes:
• The value is in electrical degrees. The electrical angle
equals the mechanical angle multiplied by the number of
motor pole pairs.
• This parameter is valid only for permanent magnet motors.
0 deg
0…360 deg
Angle offset.
1 = 1 deg
99
Motor configuration settings.
Selects the motor type.
Note:
This parameter cannot be changed while the drive is
running.
b2)
Asynchronous
motor
Standard squirrel cage AC induction motor (asynchronous
induction motor).
0
Permanent magnet
motor
Permanent magnet motor. Three-phase AC synchronous
motor with permanent magnet rotor and sinusoidal BackEMF
voltage.
1
SynRM
Synchronous reluctance motor. Three-phase AC
synchronous motor with salient pole rotor without permanent
magnets.
2
Selects the motor control mode.
DTC
Direct torque control. This mode is suitable for most
applications.
Note:
For the step-up applications SMC control mode must
be selected.
See also section
(page
0
SMC
Submersible motor control designed with step-up transformer,
sine-filter and long motor cable.
Note:
Hardware settings are set separately in group
for the transformation ration settings and
selection of sine-filter type.
1
Defines the nominal motor current. his setting must match the
value on the rating plate of the motor. If multiple motors are
connected to the drive, enter the total current of the motors.
Notes:
• Correct motor operation requires that the magnetizing
current of the motor does not exceed 90% of the nominal
current of the drive.
• This parameter cannot be changed while the drive is
running.
0.0 A
0.0 … 32767.0 A
Nominal current of the motor. The allowable range is 1/6…2 ×
I
N
(nominal current) of the drive (0…2 ×
I
N
with scalar control
mode).
1 = 1 A
No.
Name/Value
Description
Def
/
FbEq16
Содержание ACS880-01 Series
Страница 1: ...ABB industrial drives Firmware manual ACS880 ESP control program option N5600 ...
Страница 4: ......
Страница 12: ...12 Table of contents ...
Страница 20: ...20 Introduction to the manual ...
Страница 22: ...22 Using the control panel ...
Страница 28: ...28 Control locations and operating modes ...
Страница 145: ...Application macros 145 Fieldbus control macro This application macro is not supported by the current firmware version ...
Страница 146: ...146 Application macros ...
Страница 502: ...502 Parameters ...
Страница 606: ...606 Fault tracing ...
Страница 662: ...662 Control chain diagrams ...
Страница 664: ...Contact us www abb com drives www abb com drivespartners 3AXD50000041193 Rev A EN EFFECTIVE 2017 06 30 ...