![ABB ACS880-01 Series Скачать руководство пользователя страница 394](http://html.mh-extra.com/html/abb/acs880-01-series/acs880-01-series_firmware-instructions_2621394.webp)
394 Parameters
Selects the node address of the drive for master/follower
communication. No two nodes on-line may have the same
address.
Note:
The allowable addresses for the master are 0 and 1.
The allowable addresses for followers are 2…60.
1
1…254
Node address.
Defines the role of the drive on the master/follower or drive-
to-drive link.
Not in use
Master/follower functionality not active.
0
DDCS master
The drive is the master on the master/follower (DDCS) link.
1
DDCS follower
The drive is a follower on the master/follower (DDCS) link.
2
D2D master
The drive is the master on the drive-to-drive (D2D) link.
Note:
This setting is only to be used with D2D communication
implemented by application programming. If you are using the
master/follower functionality (see page
) through the XD2D
connector, select
instead.
3
D2D follower
The drive is a follower on the drive-to-drive (D2D) link.
Note:
This setting is only to be used with D2D communication
implemented by application programming. If you are using the
master/follower functionality (see page
) through the XD2D
connector, select
instead.
4
DDCS forcing
The role of the drive on the master/follower (DDCS) link is
defined by parameters
and
.
5
D2D forcing
The role of the drive on the drive-to-drive (D2D) link is defined
by parameters
.
Note:
This setting is only to be used with D2D communication
implemented by application programming. If you are using the
master/follower functionality (see page
) through the XD2D
connector, select
instead.
6
Selects the topology of the master/follower link.
Note:
if using the master/follower
functionality (see page
) through the XD2D connector (as
opposed to a fiber optic link).
Ring
The devices are connected in a ring topology. Forwarding of
messages is enabled.
0
Star
The devices are connected in a star topology (for example,
through a branching unit). Forwarding of messages is
disabled.
1
Defines the light intensity of the transmission LED of RDCO
module channel CH2. (This parameter is effective only when
parameter
is set to
. FDCO modules have a hardware transmitter current
selector.)
In general, use higher values with longer fiber optic cables.
The maximum setting is applicable to the maximum length of
the fiber optic link. See
Specifications of the fiber optic
(page
).
10
1…15
Light intensity.
No.
Name/Value
Description
Def
/
FbEq16
Содержание ACS880-01 Series
Страница 1: ...ABB industrial drives Firmware manual ACS880 ESP control program option N5600 ...
Страница 4: ......
Страница 12: ...12 Table of contents ...
Страница 20: ...20 Introduction to the manual ...
Страница 22: ...22 Using the control panel ...
Страница 28: ...28 Control locations and operating modes ...
Страница 145: ...Application macros 145 Fieldbus control macro This application macro is not supported by the current firmware version ...
Страница 146: ...146 Application macros ...
Страница 502: ...502 Parameters ...
Страница 606: ...606 Fault tracing ...
Страница 662: ...662 Control chain diagrams ...
Страница 664: ...Contact us www abb com drives www abb com drivespartners 3AXD50000041193 Rev A EN EFFECTIVE 2017 06 30 ...