![ABB ACS880-01 Series Скачать руководство пользователя страница 270](http://html.mh-extra.com/html/abb/acs880-01-series/acs880-01-series_firmware-instructions_2621270.webp)
270 Parameters
Defines the integration time of the speed controller. The
integration time defines the rate at which the controller output
changes when the error value is constant and the
proportional gain of the speed controller is 1. The shorter the
integration time, the faster the continuous error value is
corrected.
Setting the integration time to zero disables the I-part of the
controller. This is useful to do when tuning the proportional
gain; adjust the proportional gain first, then return the
integration time.
The integrator has anti-windup control for operation at a
torque or current limit.
The figure below shows the speed controller output after an
error step when the error remains constant.
2.50 s;
5.00
(
b1/b2)
Note:
This parameter is automatically set by the speed
controller autotune function. See section
(page
).
0.00 … 1000.00 s
Integration time for speed controller.
10 = 1 s
No.
Name/Value
Description
Def
/
FbEq16
K
p
× e
K
p
× e
%
e = Error value
Time
Gain = K
p
= 1
T
I
= Integration time > 0
T
D
= Derivation time = 0
Controller output
T
I
Содержание ACS880-01 Series
Страница 1: ...ABB industrial drives Firmware manual ACS880 ESP control program option N5600 ...
Страница 4: ......
Страница 12: ...12 Table of contents ...
Страница 20: ...20 Introduction to the manual ...
Страница 22: ...22 Using the control panel ...
Страница 28: ...28 Control locations and operating modes ...
Страница 145: ...Application macros 145 Fieldbus control macro This application macro is not supported by the current firmware version ...
Страница 146: ...146 Application macros ...
Страница 502: ...502 Parameters ...
Страница 606: ...606 Fault tracing ...
Страница 662: ...662 Control chain diagrams ...
Страница 664: ...Contact us www abb com drives www abb com drivespartners 3AXD50000041193 Rev A EN EFFECTIVE 2017 06 30 ...