![ABB ACS880-01 Series Скачать руководство пользователя страница 604](http://html.mh-extra.com/html/abb/acs880-01-series/acs880-01-series_firmware-instructions_2621604.webp)
604 Fault tracing
0001 Maximum current limit too low.
Check settings of parameters
and
. Make sure that
>
Check that the drive is dimensioned
correctly according to the motor.
0002 Maximum speed limit or
calculated field weakening
point too low.
Check settings of parameters
•
•
•
•
•
Make sure that
•
> (0.55 ×
) >
(0.50 × synchronous speed)
•
< 0, and
• supply voltage > (0.66 ×
0003 Maximum torque limit too low.
, and the torque limits in
group
Make sure that the maximum torque limit
in force is greater than 100%.
0004 Current measurement
calibration did not finish within
reasonable time.
Contact your local ABB representative.
0005…0008 Internal error.
Contact your local ABB representative.
0009 (Asynchronous motors only)
Acceleration did not finish
within reasonable time.
Contact your local ABB representative.
000A (Asynchronous motors only)
Deceleration did not finish
within reasonable time.
Contact your local ABB representative.
000B (Asynchronous motors only)
Speed dropped to zero during
ID run.
Contact your local ABB representative.
000C (Permanent magnet motors
only) First acceleration did not
finish within reasonable time.
Contact your local ABB representative.
000D (Permanent magnet motors
only) Second acceleration did
not finish within reasonable
time.
Contact your local ABB representative.
000E…0010 Internal error.
Contact your local ABB representative.
FF7E
Follower
A follower drive has tripped.
Check the auxiliary code. Add 2 to the
code to find out the node address of the
faulted drive.
Correct the fault in the follower drive.
FF81
FB A force trip
A fault trip command has been
received through fieldbus
adapter A.
Check the fault information provided by
the PLC.
FF82
FB B force trip
A fault trip command has been
received through fieldbus
adapter B.
Check the fault information provided by
the PLC.
Code
(hex)
Fault
Cause
What to do
Содержание ACS880-01 Series
Страница 1: ...ABB industrial drives Firmware manual ACS880 ESP control program option N5600 ...
Страница 4: ......
Страница 12: ...12 Table of contents ...
Страница 20: ...20 Introduction to the manual ...
Страница 22: ...22 Using the control panel ...
Страница 28: ...28 Control locations and operating modes ...
Страница 145: ...Application macros 145 Fieldbus control macro This application macro is not supported by the current firmware version ...
Страница 146: ...146 Application macros ...
Страница 502: ...502 Parameters ...
Страница 606: ...606 Fault tracing ...
Страница 662: ...662 Control chain diagrams ...
Страница 664: ...Contact us www abb com drives www abb com drivespartners 3AXD50000041193 Rev A EN EFFECTIVE 2017 06 30 ...