468 Parameters
(Visible when an absolute encoder is selected)
Selects the serial link mode with an EnDat or SSI encoder.
Initial position
Single position transfer mode (initial position).
0
Continuous
Continuous position data transfer mode.
1
Continuous speed
and position
Continuous speed and position data transfer mode. This
setting is intended for EnDat 2.2 encoders without sin/cos
signals.
Note:
This setting requires an FEN-11 interface revision H or
later.
2
(Visible when an absolute encoder is selected)
Selects the maximum encoder calculation time for an EnDat
encoder.
Note:
This parameter needs to be set only when an EnDat
encoder is used in continuous mode, ie. without incremental
sin/cos signals (supported only as encoder 1). See also
parameter
10 us
10 microseconds.
0
100 us
100 microseconds.
1
1 ms
1 millisecond.
2
50 ms
50 milliseconds.
3
(Visible when an absolute encoder is selected)
Selects the transmission cycle for an SSI encoder.
Note:
This parameter needs to be set only when an SSI
encoder is used in continuous mode, ie. without incremental
sin/cos signals (supported only as encoder 1). See also
parameter
50 us
50 microseconds.
0
100 us
100 microseconds.
1
200 us
200 microseconds.
2
500 us
500 microseconds.
3
1 ms
1 millisecond.
4
2 ms
2 milliseconds.
5
(Visible when an absolute encoder is selected)
Defines the length of an SSI message. The length is defined
as the number of clock cycles. The number of cycles can be
calculated by adding 1 to the number of bits in an SSI
message frame.
2
2…127
SSI message length.
-
(Visible when an absolute encoder is selected)
With an SSI encoder, defines the location of the MSB (most
significant bit) of the position data within an SSI message.
1
1…126
Position data MSB location (bit number).
-
(Visible when an absolute encoder is selected)
With an SSI encoder, defines the location of the MSB (most
significant bit) of the revolution count within an SSI message.
1
1…126
Revolution count MSB location (bit number).
-
(Visible when an absolute encoder is selected)
Selects the data format for an SSI encoder.
Binary
Binary code.
0
No.
Name/Value
Description
Def
/
FbEq16
Содержание ACS880-01 Series
Страница 1: ...ABB industrial drives Firmware manual ACS880 ESP control program option N5600 ...
Страница 4: ......
Страница 12: ...12 Table of contents ...
Страница 20: ...20 Introduction to the manual ...
Страница 22: ...22 Using the control panel ...
Страница 28: ...28 Control locations and operating modes ...
Страница 145: ...Application macros 145 Fieldbus control macro This application macro is not supported by the current firmware version ...
Страница 146: ...146 Application macros ...
Страница 502: ...502 Parameters ...
Страница 606: ...606 Fault tracing ...
Страница 662: ...662 Control chain diagrams ...
Страница 664: ...Contact us www abb com drives www abb com drivespartners 3AXD50000041193 Rev A EN EFFECTIVE 2017 06 30 ...