![ABB ACS880-01 Series Скачать руководство пользователя страница 321](http://html.mh-extra.com/html/abb/acs880-01-series/acs880-01-series_firmware-instructions_2621321.webp)
Parameters 321
Displays the actual present value of value counter 1.
The value of the source selected by parameter
is read at one-second intervals and added
to the counter. A divisor can be applied to the count (see
).
When the counter exceeds the limit set by
is set to 1.
is also given if enabled by
.
The counter can be reset from the Drive composer PC tool, or
from the control panel by keeping Reset depressed for over 3
seconds.
-
-2147483008 …
2147483008
Actual present value of value counter 1.
-
Sets the limit for value counter 1.
With a positive limit, bit 4 of
is set to 1
(and a warning optionally generated) when the counter is
equal or greater than the limit.
With a negative limit, bit 4 of
is set to 1
(and a warning optionally generated) when the counter is
equal or smaller than the limit.
0 = Counter disabled.
0
-2147483008 …
2147483008
Limit for value counter 1.
-
Configures value counter 1.
0000b
0000b…0011b
Value counter 1 configuration word.
1 = 1
Selects the signal to be monitored by value counter 1.
Not selected
None (counter disabled).
0
Motor speed
(see page
).
1
). -
Defines a divisor for value counter 1. The value of the
monitored signal is divided by this value before integration.
1.000
0.001 …
2147483.000
Divisor for value counter 1.
-
No.
Name/Value
Description
Def
/
FbEq16
Bit
Function
0
Counter mode
0 = Loop: When the limit is reached, the counter is reset. The counter status (bit 4 of
) switches to 1 for one second. The warning (if enabled) stays active for at least 10
seconds.
1 = Saturate: When the limit is reached, the counter status (bit 4 of
) switches to 1,
and remains so until
is reset. The warning (if enabled) also stays active until
is reset.
1
Warning enable
0 = Disable: No warning is given when the limit is reached
1 = Enable: A warning (see
) is given when the limit is reached
2…15
Reserved
Содержание ACS880-01 Series
Страница 1: ...ABB industrial drives Firmware manual ACS880 ESP control program option N5600 ...
Страница 4: ......
Страница 12: ...12 Table of contents ...
Страница 20: ...20 Introduction to the manual ...
Страница 22: ...22 Using the control panel ...
Страница 28: ...28 Control locations and operating modes ...
Страница 145: ...Application macros 145 Fieldbus control macro This application macro is not supported by the current firmware version ...
Страница 146: ...146 Application macros ...
Страница 502: ...502 Parameters ...
Страница 606: ...606 Fault tracing ...
Страница 662: ...662 Control chain diagrams ...
Страница 664: ...Contact us www abb com drives www abb com drivespartners 3AXD50000041193 Rev A EN EFFECTIVE 2017 06 30 ...