Operating IntegratorRD Workstations
108
Initiating a Call Alert
The dispatcher can send a call alert to another radio from the SDC Call submenu, from the
main video screen, if programmed to do so, or from the Subscriber List window if
enabled. The dispatcher first selects the channel that is used for the transmission, enters
the destination radio ID (either by manual key entry or a Subscriber ID alias button), then
click CALL ALERT. If the message is successfully sent, “
Alert OK
” is displayed. If not
successful, “
Alert Fail
” is displayed.
Sending a Status Message
If the SDC network supports status calls, the dispatcher can send a status call to another
radio from the SDC Call submenu, or from the Subscriber List window. The dispatcher
first selects the channel that is used for the transmission, enters the destination radio ID
(either by manual key entry or a Subscriber ID alias button), then click STATUS SELECT.
This brings up a Status call selection submenu or subwindow, which shows any
programmed SDC Status ID aliases (see
and
ID button or entering the status code (1-20) manually, click “Send Status” to send the
message. Click “Exit” to return to the main SDC Call submenu, or to the main Subscriber
List window.
Figure 31: SDC Status Select Submenu
Summary of Contents for 4000 Sereis
Page 1: ...Series 4000 Communication Control System Operation Version 5 6 025 9535L...
Page 7: ...7 Contents Appendix A Glossary 149 Paging Glossary 149 General Glossary 150 Index 153...
Page 8: ...Contents 8 025 9535L...
Page 16: ...Introduction 16 025 9535L...
Page 99: ...99 Operation Figure 23 iDEN Status Select Submenu Figure 24 iDEN Status Select Subwindow...
Page 152: ...Appendix A Glossary 152 025 9535L...