n8-94: Flux Position Estimation Method
No.
(Hex.)
Name
Description
Default
(Range)
n8-94
(012D)
Expert
Flux Position Estimation
Method
Sets the criteria that the drive uses to find changes in speed or load. Usually it is not necessary to
change this setting.
1
(0, 1)
0 : Softstarter
1 : Speed Feedback
Set
n8-57 = 1 [HFI Overlap Selection = Enabled]
to enable this parameter. Increases the stability when the speed or
load suddenly change, for example with rapid acceleration/deceleration or impact loads.
■
n8-95: Flux Position Est Filter Time
No.
(Hex.)
Name
Description
Default
(Range)
n8-95
(012E)
Expert
Flux Position Est Filter Time
Sets the time constant of the filter used for the recognition criteria value for speed and load changes.
Usually it is not necessary to change this setting.
30 ms
(0 - 100 ms)
Note:
Enabled when
n8-94 = 1 [Flux Position Estimation Method = Speed Feedback]
.
◆
nA: PM Motor Control Tuning
nA parameters
make adjustments for controlling PM motors.
■
nA-01: Observer Calc Gain 3
No.
(Hex.)
Name
Description
Default
(Range)
nA-01
(3129)
Expert
Observer Calc Gain 3
Sets the gain for speed estimation. Usually it is not necessary to change this setting.
30.0
(0.0 - 1000.0)
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Summary of Contents for GA500 series
Page 2: ...This Page Intentionally Blank 2 YASKAWA TOEPYAIGA5002A GA500 Programming...
Page 456: ...2 12 T Auto Tuning 456 YASKAWA TOEPYAIGA5002A GA500 Programming...
Page 488: ...3 8 Test Run Checklist 488 YASKAWA TOEPYAIGA5002A GA500 Programming...
Page 494: ...4 3 Remove and Reattach the Keypad 494 YASKAWA TOEPYAIGA5002A GA500 Programming...
Page 514: ...5 6 Connect the Drive to a PC 514 YASKAWA TOEPYAIGA5002A GA500 Programming...
Page 525: ...YASKAWA TOEPYAIGA5002A GA500 Programming 525...