1.22 Parameters Changed by PM Motor Code Selection
YASKAWA
TOEPYAIGA5002A GA500 Programming
129
No.
Name
Unit
Motor Code (setting value of E5-01)
E5-05
PM Motor Resistance (ohms/phase)
Ω
3.340
1.560
0.541
E5-06
PM d-axis Inductance (mH/phase)
mH
6.58
3.82
2.24
E5-07
PM q-axis Inductance (mH/phase)
mH
6.58
3.82
2.24
E5-09
PM Back-EMF Vpeak (mV/(rad/s))
mVs/rad
0.0
0.0
0.0
E5-24
PM Back-EMF L-L Vrms (mV/rpm)
mV/min
-1
26.3
31.0
32.9
E1-04
Maximum Output Frequency
Hz
180.0
180.0
180.0
E1-05
Maximum Output Voltage
V
200.0
200.0
200.0
E1-06
Base Frequency
Hz
180.0
180.0
180.0
E1-09
Minimum Output Frequency
Hz
18.0
18.0
18.0
L3-24
Motor Accel Time @ Rated Torque
s
0.100
0.100
0.100
n5-02
Motor Inertia Acceleration Time
s
0.100
0.100
0.100
n8-49
Heavy Load Id Current
%
0.0
0.0
0.0
◆
Yaskawa SSR1 Series IPM Motors (Derated Torque)
Table 1.9 SSR1 Series Motor Code Setting for Specification of 200 V at 1750 min
-1
(r/min)
No.
Name
Unit
Motor Code (setting value of E5-01)
E5-01
PM Motor Code Selection
-
1202
1203
1205
1206
1208
120A
Voltage Class
V
200
200
200
200
200
200
Capacity
kW
0.4
0.75
1.5
2.2
3.7
5.5
Motor Rotation Speed
min
-1
1750
1750
1750
1750
1750
1750
E5-02
PM Motor Rated Power
kW
0.4
0.75
1.5
2.2
3.7
5.5
E5-03
PM Motor Rated Current
(FLA)
A
1.77
3.13
5.73
8.44
13.96
20.63
E5-04
PM Motor Pole Count
-
6
6
6
6
6
6
E5-05
PM Motor Resistance (ohms/
phase)
Ω
8.233
2.284
1.470
0.827
0.455
0.246
E5-06
PM d-axis Inductance (mH/
phase)
mH
54.84
23.02
17.22
8.61
7.20
4.86
E5-07
PM q-axis Inductance (mH/
phase)
mH
64.10
29.89
20.41
13.50
10.02
7.43
E5-09
PM Back-EMF Vpeak (mV/
(rad/s))
mVs/rad
223.7
220.3
240.8
238.0
238.7
239.6
E5-24
PM Back-EMF L-L Vrms
(mV/rpm)
mV/min
-1
0.0
0.0
0.0
0.0
0.0
0.0
E1-04
Maximum Output Frequency
Hz
87.5
87.5
87.5
87.5
87.5
87.5
E1-05
Maximum Output Voltage
V
190.0
190.0
190.0
190.0
190.0
190.0
E1-06
Base Frequency
Hz
87.5
87.5
87.5
87.5
87.5
87.5
E1-09
Minimum Output Frequency
Hz
4.4
4.4
4.4
4.4
4.4
4.4
L3-24
Motor Accel Time @ Rated
Torque
s
0.092
0.076
0.051
0.066
0.075
0.083
n5-02
Motor Inertia Acceleration
Time
s
0.092
0.076
0.051
0.066
0.075
0.083
n8-49
Heavy Load Id Current
%
-7.6
-11.5
-9.1
-19.0
-18.7
-23.4
*1
The default setting changes when the setting for
o2-04 [Drive Model Selection]
changes.
Summary of Contents for GA500 series
Page 2: ...This Page Intentionally Blank 2 YASKAWA TOEPYAIGA5002A GA500 Programming...
Page 456: ...2 12 T Auto Tuning 456 YASKAWA TOEPYAIGA5002A GA500 Programming...
Page 488: ...3 8 Test Run Checklist 488 YASKAWA TOEPYAIGA5002A GA500 Programming...
Page 494: ...4 3 Remove and Reattach the Keypad 494 YASKAWA TOEPYAIGA5002A GA500 Programming...
Page 514: ...5 6 Connect the Drive to a PC 514 YASKAWA TOEPYAIGA5002A GA500 Programming...
Page 525: ...YASKAWA TOEPYAIGA5002A GA500 Programming 525...