A
ht
1
o
peration Guide
A-24
5.3 Setting Option parameters
The following example shows the option parameters setting method when using CC-Link. The same setting
method is used for DeviceNet.
n
NOTE
Power must be turned off and then back on to
enable changes made to Option parameters.
1
On the main menu screen, select
"Parameter".
The "Parameter" menu screen opens showing
selectable parameter groups.
2
Move the cursor to "Option
parameter" and press
.
The currently set Option parameters are
displayed.
(The display contents differ depending on
the installed option.)
Run parameter
I/O parameter
Option parameter
Servo parameter
Parameter
NRM
[01]
CC-Link
Node
Speed
INVALID
1
10M
-
-
bps
Option parameter
NRM
[01]
"Option parameter"
Step 2
24A26-M0-00
3
Move the cursor to "CC-Link" and
press
.
The CC-Link settings can now be changed.
CC-Link
Node
Speed
INVALID
1
10M
-
-
bps
VALID
INVALID
Option parameter
NRM
[01]
"CC-Link"screen
Step 3
24A27-M0-00
4
Change the parameter.
Selectable options are displayed in the
comment area. Use
or
to select
"Valid" and press
.
Change the node number and speed as
needed.
5
Press
CLR
.
This returns to the "Parameter" menu screen.