5
o
peration
5-26
Speed
Position
100mm
P1
(0mm)
100%
100%
P2
(200mm)
100mm
100mm
Setting example 3
Posit pitch feed
A
B
C
23527-M0-00
No.
RUN type
Position [mm]
Speed [%]
Accel. [%]
Decel. [%]
P1
ABS
0
100
100
100
P2
ABS
200
100
75
100
P3
INC
100
100
100
100
A: P1 P2 positioning occurs.
B: Pitch feed corresponding to the P3 movement amount occurs.
C: Return to P1.
Speed
Position
P1
(0mm)
100%
100%
10%
P2
(200mm)
P4
(500mm)
P3
(400mm)
Setting example 4
Merge operation
A
B
23528-M0-00
No.
RUN type
Position [mm]
Speed [%]
Accel. [%]
Decel. [%]
Jump
P1
ABS
0
100
100
100
0
P2
ABS Merge
200
100
100
100
3
P3
ABS Merge
400
10
100
100
4
P4
ABS
500
100
100
100
0
A: Merge operation from P1 P2 P3 P4.
B: Return to P1.