7
Specifications
7-1
1. Controller basic specifications
1.1 Basic specifications
1.1.1
TS-S
TS-S2
TS-SH
Item
TS-S
TS-S2
TS-SH
Controllable robot
*1
TRANSERVO series
Current consumption
2.5A (Max. 4.5A)
3.5A (Max. 6.5A)
Dimensions
W30×H162×D82mm
W30×H162×D123mm
Weight
Approx. 0.2kg
Approx. 0.3kg
Control power supply
24V DC ±10%
Main power supply
24V DC ±10%
Control method
Closed loop vector control method
Position detection
method
Resolver (resolution: 20480 P/r)
*3
Multi-turn resolver with absolute position function
(resolution: 20480 P/r)
*3
Operation mode
Positioning operation by specifying point number, Direct positioning command
Types of operation
Positioning, merge-positioning, push, and jog operations
Number of points
255
Point type setting
1) Standard setting : Set speed and acceleration in percent of the respective maximum settings.
2) Custom setting : Set speed and acceleration in SI units.
Point teaching
Manual data input (coordinate input), teaching, direct teaching
I/O interface
Selectable from the following: NPN, PNP, CC-Link, DeviceNet, EtherNet/IP
*2
.
Input
Servo ON (SERVO), reset (RESET), start (START), interlock (/LOCK), origin search (ORG),
manual mode (MANUAL), jog motion - (JOG-), jog (JOG+), point number selection (PIN0 to PIN7)
Output
Servo status (SRV-S), alarm (/ALM), operation end (END), operation in progress (BUSY),
control output (OUT0 - OUT3), point number output 0 to 7 (POUT0 - POUT7)
Communication
RS-232C, 1 channel
Power for brake
-
Emergency stop
circuit
Emergency stop input, emergency stop contact output (1 system: When the HT1 is used.)
Protection function
Position detection error, overheat, overload, overvoltage, low voltage, position deviation, over current,
motor current error, motor line disconnection, enc. power down
*4
Ambient operating
temperature and
humidity
0 to 40˚C, 35 to 85% RH (no condensation)
Storage ambient
temperature and
humidity
-10 to 65˚C, 10 to 85% RH (no condensation)
Atmosphere
Indoor, not exposed to direct sunlight. No corrosive gas, inflammable gas, oil mist, and dust particles
should be present.
Vibration resistance
10 to 57Hz in each of XYZ directions, single amplitude 0.075mm, 57 to 150Hz, 9.8m/s
2
Protective structure
-
*1. For "controlled robot" details, see section "1.2 List of controlled robots".
*2. EtherNet/IP options cannot be installed into the TS-S. They are applicable to the models from TS-S2.
*3. This value may vary depending on the model.
*4. “ENC. POWER DOWN” error is a protective function that is intended only for TS-SH.