4
I/
o
signal functions
4-2
1.2 CC-Link type
Operation occurs as a CC-Link remote device station, on a one-unit to one-station basis.
n
NOTE
"Station No." and "baud rate" settings must be specified in order for the TS series to be recognized as remote
station in the CC-Link system. These settings can be specified in the support software (TS-Manager), or from the
HT1. (For the setting procedure, see section 5.3 "Setting Option parameters".
Remote I/O (bit I/O)
n
Input (Master Remote)
Output (Remote Master)
No.
Signal Name
Description
No.
Signal Name
Description
RYn0
PIN0
Point No. select
RXn0
POUT0
Point No. output
RYn1
PIN1
RXn1
POUT1
RYn2
PIN2
RXn2
POUT2
RYn3
PIN3
RXn3
POUT3
RYn4
PIN4
RXn4
POUT4
RYn5
PIN5
RXn5
POUT5
RYn6
PIN6
RXn6
POUT6
RYn7
PIN7
RXn7
POUT7
RYn8
JOG+
JOG movement (+ direction)
RXn8
OUT0
Control output
RYn9
JOG-
JOG movement (- direction)
RXn9
OUT1
RYnA
MANUAL
MANUAL mode
RXnA
OUT2
RYnB
ORG
Return-to-origin
RXnB
OUT3
RYnC
/LOCK
Interlock
RXnC
BUSY
Operation-in-progress
RYnD
START
Start
RXnD
END
Operation-end
RYnE
RESET
Reset
RXnE
/ALM
Alarm
RYnF
SERVO
Servo ON
RXnF
SRV-S
Servo status
RY(n+1)0
-
-
RX(n+1)0
-
-
RY(n+1)1
-
-
RX(n+1)1
-
-
RY(n+1)2
-
-
RX(n+1)2
-
-
RY(n+1)3
-
-
RX(n+1)3
-
-
RY(n+1)4
-
-
RX(n+1)4
-
-
RY(n+1)5
-
-
RX(n+1)5
-
-
RY(n+1)6
-
-
RX(n+1)6
-
-
RY(n+1)7
-
-
RX(n+1)7
-
-
RY(n+1)8
-
-
RX(n+1)8
-
-
RY(n+1)9
-
-
RX(n+1)9
-
-
RY(n+1)A
-
-
RX(n+1)A
-
-
RY(n+1)B
-
-
RX(n+1)B
R-RDY
Remote READY
RY(n+1)C
-
-
RX(n+1)C
-
-
RY(n+1)D
-
-
RX(n+1)D
-
-
RY(n+1)E
-
-
RX(n+1)E
-
-
RY(n+1)F
-
-
RX(n+1)F
-
-
n: Value determined by CC-Link station No. setting.