3
Data setting
3-13
• Return-to-origin related parameters
K13
Return-to-origin speed
Setting Range
Default
Units
Restart
0.01 to 100.00
Depends on robot type
mm/s
-
Function
Specifies the return-to-origin movement speed.
c
CAutIoN
An alarm may occur during return-to-origin operation if the return-to-origin speed is set too high. Always set it to
an appropriate value.
K14
Return-to-origin direction
Setting Range
Default
Units
Restart
0 to 1
Depends on robot type
-
-
Function
Specifies the return-to-origin direction.
Settings
Setting Value
Description
0
CCW
1
CW
K15
Origin Coordi.
Setting Range
Default
Units
Restart
0 to 1
0
-
-
Function
Specifies the coordinate system polarity.
Settings
Setting Value
Description
0
Standard (Plus-polarity is opposite direction from return-to-origin direction.)
1
Reverse (Plus-polarity is same direction as return-to-origin direction)
K16
Origin shift
Setting Range
Default
Units
Restart
Other than TS-P : -9999.99 to 9999.99
TS-P
: -9999.999 to 9999.999
Other than TS-P : 0.00
TS-P
: 0.000
mm
-
Function
Specifies the coordinates of the return-to-origin end position.
• Speed switch
K17
Speed switch function
Setting Range
Default
Units
Restart
0 to 1
0
-
-
Function
Enables/disables the speed switch function.
Settings
Settings
Description
0
Disable
1
Enable
c
CAutIoN
this function is available from controller's software version 1.06.111 onwards. this parameter can be changed
from the ht1 with software version 1.09 onwards and the tS-Manager with software version 1.2.1 onwards.