5
o
peration
5-23
3.8 Speed switch function
The overall positioning operation speed can be switched between two levels from the host equipment by using
the speed switch input (SPD).
Assigning method
n
When you set the "Speed switch function" (K17) to "Enable", the speed switch (SPD) will be assigned to JOG+ input. SPD
will be ON at the same time as the selection of point number, and the positioning operation will be performed at the
speed calculated by multiplying the current speed by the value specified at "Switched speed" (K18).
SPD
Speed
OFF
Speed 1 = Specified speed
ON
Speed 2 = Specified speed×Switched speed (K18) / 100
n
NOTE
• Cannot be assigned in the manual mode (MANUAL=ON).
• Specified speed means "speed data specified at each point data×speed override (K9) / 100".
Timing chart
n
Operation-in-progress
(BUSY)
START
Switched speed
(SPD)
Speed 1
Speed 2
Operation end (END)
Td
00h
00h
Point No. select
(PIN0 to PIN7)
Setting
Setting
00h
Td
ON
OFF
Speed switch function
23524-M0-00
c
CAutIoN
this function is available from controller's software version 1.06.111 onwards.