3
Data setting
3-15
K25
POUT select
Setting Range
Default
Units
Restart
0 to 2
1
-
Required
Function
Specifies the output timing for the POUT0 to POUT7 point No. outputs.
Settings
Setting Value
Description
0
No output
1
Output at positioning end (AFTER)
2
Output at movement start (WITH)
• Function selection related parameters
K30
Alarm No. output function
Setting Range
Default
Units
Restart
0 to 1
0
-
-
Function
Enables/disables the alarm No. output function.
Settings
Setting Value
Description
0
Disable
1
Enable
TIP
For details regarding alarm No. outputs, see section 7.3, "Alarm No. output function", in Chapter 5.
K31
SERVO sequence
Setting Range
Default
Units
Restart
0 to 1
0
-
-
Function
Specifies the SERVO input's servo ON/OFF conditions.
Settings
Setting Value
Description
0
Edge (servo ON at leading edge, servo OFF at trailing edge)
1
Level (ON: servo on; OFF: servo off)
K32
JOG response time
Setting Range
Default
Units
Restart
0 to 1000
0
ms
-
Function
Specifies the JOG movement sequence at JOG+/JOG- inputs.
Settings
Setting Value
Description
0
JOG operation only
1 to 1000
Inching ope JOG operation after specified time elapses
K33
Input filter
Setting Range
Default
Units
Restart
1 to 10
2
ms
-
Function
Specifies the filter processing time for inputs from the host unit. The larger the setting value, the longer the filtering time,
and the slower the response to the input.
K38
Node (controller)
Setting Range
Default
Units
Restart
1 to 16
1
-
-
Function
Specifies the node number for a daisy-chained controller.