5
o
peration
5-39
5.7 Parameter data writing
Parameter data is written.
Input
Command Option
Command
WIN3
WIN2
WIN1
WIN0
Data
Parameter No.
0400h
Output
Command Response
Status
WOUT3
WOUT2
WOUT1
WOUT0
-
-
0200h
Command type and data
n
Command (WIN0)
Command Option
Unit
Parameter No. (WIN1)
Data (WIN2, WIN3)
0400h
0003h
In-position (K3)
Other than TS-P : 0.01mm
TS-P
: 0.001mm
0004h
Push mode (K4)
-
0005h
Push judge time (K5)
ms
0006h
Push speed (K6)
0.01mm/s
0007h
ZONE (-) (K7)
Other than TS-P : 0.01mm
TS-P
: 0.001mm
0008h
ZONE (+) (K8)
Other than TS-P : 0.01mm
TS-P
: 0.001mm
0009h
Speed override (K9)
%
000Ah
JOG speed (K10)
%
000Bh
Inching width (K11)
Other than TS-P : 0.01mm
TS-P
: 0.001mm
000Ch
MOVE output level (K12)
0.01mm/s
c
CAutIoN
the number of write processes is limited since the parameter dada is written into the EEpRoM. So, avoid writing
parameter data unnecessarily. Additionally, the write target is a part of operation parameters related to the
positioning operation.
TIP
For parameter data details, see section 4, "Parameter data", in Chapter 3.
n
NOTE
0003h to 0008h, and 000Ch of the writable parameters are available from controller’s software version Ver.1.11.125.