2-25
OVERLOAD WARNING LIGHT
INSP
ADJ
3. Check for blockages in the cooling air inlet
and around the control unit. If any block-
ages are found, remove.
4. After checking, restart the engine.
TIP
The overload warning light may come on for a
few seconds at first when using electric
devices that require a large starting current,
such as a compressor or a submergible pump.
However, this is not a malfunction.
5. Check:
9
Overload warning light
1
lighting
6. Remove:
9
Fuel cock knob
9
Control panel
9
Overload warning light connector
Refer to “CONTROL PANEL” in CHAP-
TER 3.
å
For Canada and Australia
∫
For Europe and Korea
Checking steps:
9
Connect a size AA battery (1.5 V) to the
overload warning light lead.
9
Check that the overload warning light
1
turns on.
Does not turn on
→
Replace.
TIP
battery (+)
→
Yellow lead
a
battery (–)
→
Black/White lead
b
7. Install:
9
Overload warning light connector
9
Control panel
Refer to “CONTROL PANEL” in CHAP-
TER 3.
9
Fuel cock knob
å
For Canada and Australia
∫
For Europe and Korea
1
1
A
B
a
b
1
a
b
A
B
7DK40-02 6/15/09 2:58 PM Page 51
Summary of Contents for EF2000iS - Inverter Generator
Page 2: ...7DK40 Cover 4 6 09 9 18 AM Page 2 ...
Page 13: ...7DK40 00 6 15 09 2 54 PM Page 11 ...
Page 17: ...7DK40 00 6 15 09 2 54 PM Page 15 ...
Page 21: ...7DK40 00 6 15 09 2 54 PM Page 19 ...
Page 223: ...ELEC 7DK40 05 6 12 09 6 01 PM Page 41 ...
Page 233: ...ELEC 7DK40 05 6 12 09 6 01 PM Page 51 ...
Page 255: ...TRBL 7DK40 06 6 15 09 10 30 AM Page 22 ...
Page 310: ...7DK40 07 6 15 09 3 01 PM Page 55 ...
Page 311: ...7DK40 Cover 4 6 09 9 18 AM Page 2 ...