5-17
ELEC
IGNITION SYSTEM
8. Oil level switch
9
Remove the oil level switch from the bottom
of the crankcase.
Refer to “CRANKCASE COVER AND
CAMSHAFT” in CHAPTER 3.
9
Connect the pocket tester to the oil level
switch for continuity.
Tester (+) lead
→
Black lead
1
Tester (–) lead
→
Ground
2
1
2
1
2
å
∫
å
å
Continuity
→
Correct
∫
∫
No continuity
→
Correct
9. Wire harness
9
Check the terminal of the connector for con-
tamination, rust, or disconnection.
Replace the CDI unit/ignition coil.
Replace the oil level switch.
NO CONTINUITY
CONTINUITY
Correct or replace the connector.
NOT GOOD
GOOD