WF30T
Case Former
Engineering Specifications
11-112
11 ENGINEERING SPECIFICATIONS
11.1 Operating Parameters
Table 59: Operating Parameters
Operating Parameters
Safety Guarding
Integrated safety guarding with keyed interlock switches.
Machine Construction
Aluminum, stainless steel and plated steel.
Discharge at absolute minimum 23” (584 mm). With leveling pads,
the range is 24” (610 mm) to 28.5” (724 mm).
Operation Level
Case magazine at 29” (736 mm) at minimum discharge –
comfortable loading height.
UL/cUL listed standard electrical control panel, NEMA 12.
Meets NFPA-79 standard.
Built-in 24V DC power supply for safe, low voltage operating
controls.
Controls
PLC operated sequence and timing control.
Power Requirement
Refer to electrical specification label inside electrical enclosure.
Power Cord Rating
Type 14 AWG, 4-wire, rated to 600V or equivalent
Air Requirement
0.90 ft
3
per case at 90 PSI (6 bar).
27 SCFM
Pneumatic Hose
Gauge
Minimum inside diameter of 3/4” (for flexible tubes) or 1” (for steel
tubes)
Speed
Up to 30 CPM depending on case size and case quality.
Available ‘high speed mode’ to 30 CPM.
Tape System
DEKKA Model WEX-22 tape applicator head. Other makes
optional.
Approx. Weight
1,300 lbs (590 kg).
Case Styles
RSC (Regular Slotted Case), HSC (Half Slotted Case), and CSSC
(Center Special Slotted Case); for other styles, please consult your
WEXXAR representative.
Transport / Storage
-25
º
C to 55
º
C
Operating
Temperature
0
º
C to 40
º
C
Altitude
1000 meters
Relative Humidity
50% at 40
º
C
Change-Over Time
Approximately 10 – 15 minutes.
Other
Lock-out provision on main electrical and air shutoffs. Many optional
features for the widest range of applications.
11.2 Machinery Drawings
Please refer to the Supplementary Manual for drawings specific to your machine.
11.3 Program Code
Refer to disk enclosed with this manual.
Summary of Contents for WF30T
Page 2: ...WF30T Case Former ...
Page 139: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 126 ...
Page 140: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 127 ...
Page 141: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 128 ...
Page 142: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 129 ...
Page 143: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 130 ...
Page 144: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 131 ...
Page 146: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 133 ...
Page 147: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 134 ...
Page 148: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 135 ...
Page 149: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 136 ...
Page 150: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 137 ...