WF30T Case Former
Other Machine Adjustments
8-76
Table 27: Mechanism HOME Positions
Mechanism HOME Positions
Forming Head Jaws
OPEN
Minor Flap Folder
DOWN
Injector
DOWN
Major Flap Folders
OPEN
Forming Head Assembly
UP
Discharge Pusher
BACK
Case Separator
UP
7) From the
‘Main Control’
screen of the touchscreen, press the
‘JOG CONTROL’
button. Press the
‘MACHINE CYCLE JOG’
button consecutively to step the machine
through the full cycle sequence as follows:
Table 28: Full Cycle Sequence
Full Cycle Sequence
STEP 1 Forming Head Jaws
CLOSE
STEP 2 Injector
UP
Case pushed into jaw pins
STEP 3 Injector
DOWN
Case stays in jaws.
STEP 4 Forming Head Jaws
OPEN
Case opens.
STEP 5 Forming Head Assembly
DOWN
Case in major flap folders.
STEP 6 Major Flap Folders
CLOSE
Major flaps turned in.
STEP 7 Former Head Assembly
UP
Case stays down.
STEP 8 Discharge Pusher
OUT
Case moves into side-belt
conveyor.
Discharge Pusher
BACK
Case taped shut.
STEP 9
Major Flap Folders
OPEN
The machine should form the case successfully in a step-by step manner. If a problem
should occur during any one of the above steps, analyze the reason for the problem and
adjust the machine accordingly. If necessary, refer to Section 10.3:
for further assistance.
8) When the machine successfully forms the case in the step-by-step in
JOG
mode, press
the
‘MAIN CONTROL’
button to return to the
‘Main Control’
screen. Then press the
‘START’
button to commence fully automatic operation. This completes the machine
testing after size adjustment.
NOTE: The feedbelts will remain ON for 12 seconds, and
the drivebelts and ‘READY’ text on the display will remain
ON for 15 minutes after each actuation of the ‘MACHINE
CYCLE JOG’ button. The timers are RESET each time that
the ‘MACHINE CYCLE JOG’ button is pressed. If the
‘READY’ text on the display goes out, it will be necessary to
press the button once more to return to the READY
condition before continuing the JOG step cycle sequence.
Summary of Contents for WF30T
Page 2: ...WF30T Case Former ...
Page 139: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 126 ...
Page 140: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 127 ...
Page 141: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 128 ...
Page 142: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 129 ...
Page 143: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 130 ...
Page 144: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 131 ...
Page 146: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 133 ...
Page 147: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 134 ...
Page 148: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 135 ...
Page 149: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 136 ...
Page 150: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 137 ...