WF30T Case Former
Operating Procedures
6-53
3. If required by local regulations or company policy, lock out the electrical power and air
supply before proceeding.
4. Open the guard door for access to the jammed case.
5. Remove all jammed case corrugate. Any mechanism that is entangled with the jammed
case may safely be moved by hand, as all air pressure has been exhausted.
6.
Make sure that the first case in the magazine at the separator is pushed
into the caliper slot down to the injector drive bar.
7. Close the guard door and pull out the
‘EMERGENCY STOP’
button. Remove lock-out, if
applicable.
8. Press
the
‘RESET’
button and restart the machine by following the start-up procedure in
Check the ‘S’ box for Satisfactory Performance and ‘US’ box for Unsatisfactory Performance.
Table 15: Clearing Jams
Clearing Jams
S
US
Press the
‘RESET’
button.
Press the
‘EMERGENCY STOP’
button.
Wait until air pressure has fully exhausted and all mechanisms are
stationary before proceeding.
Open the guard door for access to the jammed case.
Remove all jammed case corrugate by hand.
Make sure the first case in the magazine at the separator is pushed
into the caliper slot down to the injector drive bar.
Close the guard door.
Reset the
‘EMERGENCY STOP’
button.
Restart the machine.
WARNING!
Never attempt to remove a jammed case by reaching
in from the discharge end of the machine or around a
guard with the air pressure still switched on.
WARNING!
Be careful when clearing jams in the tape head area.
The mechanism is spring-actuated, and capable of a
powerful pinching action. It also contains a very
sharp blade.
Summary of Contents for WF30T
Page 2: ...WF30T Case Former ...
Page 139: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 126 ...
Page 140: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 127 ...
Page 141: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 128 ...
Page 142: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 129 ...
Page 143: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 130 ...
Page 144: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 131 ...
Page 146: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 133 ...
Page 147: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 134 ...
Page 148: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 135 ...
Page 149: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 136 ...
Page 150: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 137 ...