WF30T
Case Former
Troubleshooting & Repairs
- 10-106 -
Table 56: Jaw not moving
Problem
Possible Cause
Solution
Compressed
air not
connected
Connect air supply.
Mechanical
Jam
Clear mechanical jam.
Socket loose
Tighten socket.
Open Circuit
Cable broken
Replace cable.
Valve head against surface
of mounting bracket
Add a washer/spacer between the
mounting bracket and valve base.
Mechanical
interference
of valve head Valve head is being
pressed by other object
Remove object.
Overheating /
Too cold
Usual cause is high / low
ambient temperature
When ambient temperature is over 40°
or below 0° centigrade.
Auto drain of the filter is not
working; water accumulated
in the cup is not discharged
Drain water in the filter cup and fix the
auto drain valve or replace the filter
cup.
Water
Condensation
Too much water in the
air supply
Dry the air before it enters the
machine.
10.6.1 Other Typical Pneumatic Issues
Forming head and/or jaw too fast
1. Air pressure regulators set too high
•
Air pressure at machine’s main regulator should be 90 PSI.
•
Air pressure at mast regulator should be 70 PSI.
•
Air pressure at jaw regulator should be 70 PSI.
Valve malfunction: valve spool stuck / does not actuate
1. No power supply
•
Verify that the solenoid valve is connected to a DC 24 V power supply.
2. No setpoint
•
Check the control unit and connection (PLC output).
3. Valve slide stuck
•
Replace servo valve.
Valve malfunction: valve spool oscillates
1. Power supply too low
•
Ensure that the power supply is between 17-30 Volts DC.
Summary of Contents for WF30T
Page 2: ...WF30T Case Former ...
Page 139: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 126 ...
Page 140: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 127 ...
Page 141: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 128 ...
Page 142: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 129 ...
Page 143: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 130 ...
Page 144: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 131 ...
Page 146: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 133 ...
Page 147: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 134 ...
Page 148: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 135 ...
Page 149: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 136 ...
Page 150: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 137 ...