9.5 Pneumatic System Maintenance
9.5.1 Pneumatic Supply Adjustments
Little adjustment is necessary. The black knob on the top of each regulator unit adjusts the
pneumatic supply pressure. The main regulator should be set to give a pressure of 90 PSI. If the
main supply pressure regularly drops by 15 PSI while running, a larger supply air-line may be
required.
Maintenance
•
Drain the mist separator bowl frequently.
•
As the mist separator becomes contaminated, the pressure drop across the filter will
increase. Replace the element when the pressure drop reaches 15 PSI, or once per year,
whichever comes first.
•
The rate at which the filter element is contaminated will be greatly affected by the quality
of the incoming air. If the air is wet or contaminated, the filter element will need more
frequent replacement.
9.5.2 Valve Bank
Verify the following item on the valve bank:
1) Check valves for leaks and mechanical damage.
Check the ‘S’ box for Satisfactory Performance and ‘US’ box for Unsatisfactory Performance.
Table 42: Valve Bank Maintenance
Valve Bank
S
US
Check valves for leaks and mechanical damage.
9.5.3 Filter-Regulator
Verify the following item on the filter-regulator assembly:
1) Check water trap for function and filter condition.
Check the ‘S’ box for Satisfactory Performance and ‘US’ box for Unsatisfactory Performance.
Table 43: Filter-Regulator Maintenance
Filter-Regulator
S
US
Check water trap for function and filter condition.
Summary of Contents for WF30T
Page 2: ...WF30T Case Former ...
Page 139: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 126 ...
Page 140: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 127 ...
Page 141: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 128 ...
Page 142: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 129 ...
Page 143: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 130 ...
Page 144: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 131 ...
Page 146: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 133 ...
Page 147: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 134 ...
Page 148: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 135 ...
Page 149: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 136 ...
Page 150: ...WF30T Case Former Appendix B MSDS Keystone Nevastane HT 2 137 ...