CHAPTER 6 - DETAILED PARAMETER DESCRIPTION
141
Range
[Factory Setting]
Parameter
Unit
Description / Notes
The Alarm is only an indication and does not disable the motor. It
is showed on the display when the motor thermal protection level
exceeds the value adjusted in P642. It leaves this condition auto
-
matically when the thermal protection level gets below the value
adjusted in P643. This situation can be indicated via digital output.
Table 6.55
-
Selection between fault and alarm
It allows selecting protection trips between Fault and Alarm.
The Fault trips disabling the motor. It only leaves this condition
through the Reset. This condition can be indicated via digital output.
The Alarm is only showed on the display. It does not disable the
motor. It leaves this condition automatically when the alarm condition
is eliminated. This situation can be also indicated via digital output.
P706
Open DIx Protection
Trip
P716
Line Overvoltage
Trip
P732
Motor
Overtemperature –
PTC – Trip
P765
Motor Undercurrent
Trip
P766
Motor Overcurrent
Trip
P778
Motor Undertorque
Trip
P779
Motor Overtorque
Trip
P780
Motor Underpower
Trip
P781
Motor Overpower
Trip
0 to 1
[0= Fault E06]
1
0 to 1
[0= Fault E16]
1
0 to 1
[0= Fault E32]
1
0 to 1
[0= Fault E65]
1
0 to 1
[0= Fault E66]
1
0 to 1
[0= Fault E78]
1
0 to 1
[0= Fault E79]
1
0 to 1
[0= Fault E80]
1
0 to 1
[0= Fault E81]
1
P706 to P781 Description
0
Fault Exx
1
Alarm Exx
Summary of Contents for SSW06