![WEG SSW06 User Manual Download Page 10](http://html.mh-extra.com/html/weg/ssw06/ssw06_user-manual_950614010.webp)
SSW-06 - QUICK PARAMETER REFERENCE
10
Parameter
Description
Adjustable Range
Factory
Unit
User´s
Page
Setting Setting
P030
Current of Phase R
0 to 9999.9
-
A
89
P031
Current of Phase S
0 to 9999.9
-
A
89
P032
Current of Phase T
0 to 9999.9
-
A
89
P033
Line Voltage - R-S
0 to 999
-
V
89
P034
Line Voltage - S-T
0 to 999
-
V
89
P035
Line Voltage - T-R
0 to 999
-
V
89
P042
Time Powered
0 to 65535
-
h
90
P043
Time Enabled
0 to 6553,5
-
h
90
P044
kWh Counter
0 to 999.9
-
kWh
90
P045
MWh Counter
0 to 9999
-
MWh
90
P047
Maximum Starting Current
0 to 9999.9
-
A
90
P048
Average Starting Current
0 to 9999.9
-
A
90
P049
Real Starting Time
0 to 999
-
s
90
P050
Motor Thermal Protection Status
0 to 250
-
%
91
P053
Maximum Current at Full Voltage
0 to 9999.9
-
A
91
P054
Maximum Line Voltage with the
0 to 999
-
V
91
Motor Running
P055
Minimum Line Voltage with the
0 to 999
-
V
91
Motor Running
P056
Maximum Line Frequency with the
0 to 99
-
Hz
91
Motor Running
P057
Minimum Line Frequency with the
0 to 99
-
Hz
92
Motor Running
P058
Maximum Number of Starts per Hour
0 to 32
-
-
92
P059
Total Number of Starts
0 to 65535
-
-
92
P060
Current at the Last Fault
0 to 9999.9
-
A
92
P061
Voltage at the Last Fault
0 to 999
-
V
92
P062
SSW Status at the Last Fault
0 to 12
-
-
92
P063
Current at the Second Fault
0 to 9999.9
-
A
92
P064
Voltage at the Second Fault
0 to 999
-
V
92
P065
SSW Status at the Second Fault
0 to 12
-
-
92
P066
Current at the Third Fault
0 to 9999.9
-
A
92
P067
Voltage at the Third Fault
0 to 999
-
V
92
P068
SSW Status at the Third Fault
0 to 12
-
-
92
P069
Current at the Fourth Fault
0 to 9999.9
-
A
92
P070
Voltage at the Fourth Fault
0 to 999
-
V
92
P071
SSW Status at the Fourth Fault
0 to 12
-
-
92
P072
Current at the Fifth Fault
0 to 9999.9
-
A
92
P073
Voltage at the Fifth Fault
0 to 999
-
V
92
P074
SSW Status at the Fifth Fault
0 to 12
-
-
92
P075
Current at the Sixth Fault
0 to 9999.9
-
A
92
P076
Voltage at the Sixth Fault
0 to 999
-
V
92
P077
SSW Status at the Sixth Fault
0 to 12
-
-
92
P085
Fieldbus Communication
0=Off
-
-
93
Board Status
1=Board Inactive
2=Board Active and Offline
3=Board Active and Online
P088
SoftPLC Status
0=Without
-
-
93
1=Loading
2=Fault
3=Stopped
4=Running
Summary of Contents for SSW06