Reference Commands – Mailbox Commands
•
139
Table Management Commands
WAGO-I/O-SYSTEM 750
I/O Modules
3.1.4.4.4
TABLE_STOP (0x48)
Ends table processing; after this, the STOP_FAST command is executed
internally in the system.
Request
Byte 2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
MB0
0x48
MB1 T
-
MB2 Reserved
MB3 Reserved
MB4 Reserved
MB5 Reserved
Response
Byte 2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
MB0
0x48
MB1 T
Return
Code
MB2 Status
MB3 Reserved
MB4 Reserved
MB5 Reserved
0x00: OK
0x01: General
error
0x11:
The last command is still being executed
0x12:
Command not accepted, for example, when a Move
command has not yet been completed.
Return
Code
(error code
for
previous
command
SPEED_
STOP_
IMM)
0x23: Access
denied
Status
exact error code, when return code <> 0