background image

© MAXON Lift Corp. 2016

LIFT CORPORATION 

Sht. 1 of 3 DSG# 

M-16-06

  Rev. 

-

 Date: 02/22/16

INSTRUCTION, BMRA FILTER LINE FIELD FIX 

KIT P/N 297072-01

HOSE, 1/2” MP, JIC#8F TO JIC#8F

P/N 297071-01

QTY. 1

STRAIGHT FITTING

#6 O-RING, M-M JIC#8

P/N 253701

QTY. 1

45º ELBOW, JIC 37º 

#8M - NPT #6F

P/N 906965-01

QTY. 1

 

WARNING

!

To prevent accidental personal injury and equipment damage, make sure 
power is disconnected from Liftgate while installing parts.

1.

 Turn 

OFF 

the master disconnect switch at the pump 

box to disconnect battery power from the hydraulic 
pumps. Refer to 

BMRA Operation Manual

 for 

detailed instructions.

NOTE:

 This fi eld fi x kit is used to replace the steel line on the oil fi lter outlet 

in BMRA and BMRSD pump boxes. It applies to gravity down, 
power down, single pump, and dual pump models.

Reviews: