![WAGO I/O SYSTEM 750 750-671 Manual Download Page 224](http://html1.mh-extra.com/html/wago/i-o-system-750-750-671/i-o-system-750-750-671_manual_3328297224.webp)
224 •
Overview of Error Blink Codes
Auxiliary
Commands
WAGO-I/O-SYSTEM
750
I/O
Modules
Bit number
Default
Name
Dec.
Hex.
Type
Target/Source Bit no.
Description
31
0x1F
Trace_Stored 32
0x20
SRC
-
-
This bit is set when all 200 data sets
TRACE_VARI/2 have been saved in the Trace
table. Trace_Stored is cleared each time trace
recording is started (0
1 to Trace_Trigger
when Trace_Armed is also set). A trace can be
read out using the table commands
DLD_START, DLD_CONT and DLD_END.
33
0x21
34
0x22
35
0x23
36
0x24
37
0x25
38
0x26
39
0x27
Moving range exceeded when moving in
negative direction.
0:
The bottom limit for the movement range
has not been violated.
Err_Range_
Neg
40 0x28 SRC -
-
1:
The bottom limit for the movement range
has been violated.
Moving range exceeded when moving in
positive direction.
0:
The top limit for the movement range has
not been violated.
Err_Range_
Pos
41 0x29 SRC -
-
1:
The top limit for the movement range has
been violated.
Err_Range
42
0x2A SRC
-
-
Parameter is set when it has been detected by
Err_Range_Neg, Err_Range_Pos,
LimitSwitch_Pos or LimitSwitch_Neg that the
permissible movement range has been violated.
43
0x2B
44
0x2C
45
0x2D
46
0x2E
CAM9 47
0x2F
SRC
-
- Camshaft
9
Input1 48
0x30
SRC
KBUS_ST3_0
Stop1_N
0x90
0xC2
Input 1
Input2 49
0x31
SRC
KBUS_ST3_1
Set_Reference
0x91