![WAGO I/O SYSTEM 750 750-671 Manual Download Page 222](http://html1.mh-extra.com/html/wago/i-o-system-750-750-671/i-o-system-750-750-671_manual_3328297222.webp)
222 •
Overview of Error Blink Codes
Auxiliary
Commands
WAGO-I/O-SYSTEM
750
I/O
Modules
Bit number
Default
Name
Dec.
Hex.
Type
Target/Source Bit no.
Description
Start sequence in the operating mode.
0: This bit is also set to 0 when the Start
request is canceled.
1: The rising edge function is a function of
the selected operating mode.
M_Positioning (step positioning)
The currently specified setpoint in the Mode
2.2 process image has been assumed.
Movement is made directly to the new target
position, even if the drive is already turning,
(Change on the fly) when PreCalc_Ack is set,
the movement sequence has already been
precalculated and will not be started
immediately.
M_Program (MOVE program)
The Move program is started. If a Move
program is already running, it will be restarted
at the first command.
M_Reference (Reference run)
The reference run is being started. If the
reference run is still in operation, the (new)
setpoints are again accepted and calculated
(same procedure as for step positioning). The
reference run is then restarted.
M_Jog (JogMode)
No effect. The drive is started using the
pushbutton Direction_Pos or Direction_Neg.
Start_ACK 18 0x12 SRC KBUS_ST1_2
0x82
M_DriveByMbx (Mailbox mode)
No effect. Various commands can be issued via
mailbox as soon as the Mailbox mode is
activated.
Step positioning mode
0: The Step positioning mode is not active
(selected).
M_
Positioning_
ACK
19 0x13 SRC KBUS_ST1_3
0x83
1: The Step positioning mode is active.
Movement is made to the active setpoint
on the next rising edge for Start.