Slim Door Phone 

1,2 or 4 buttons 

  

  

  

  

  

  

  

  

  

Manuel 

 

 

 

 

 

 

V2.2 

find the latest version of the manual and firmware at 

www.linkcom.fr

  

 

Summary of Contents for SlimDoorPhone 1 button

Page 1: ...om France 11 rue du Soleil Levant 92140 CLAMART Copyright 2012 Linkcom Tous droits réservés 1 Slim Door Phone 1 2 or 4 buttons Manuel V2 2 find the latest version of the manual and firmware at www linkcom fr ...

Page 2: ...g name card panel 7 3 SlimDoorPhone Services 8 3 1 Signalling Overview 8 3 2 Visitor at the door 8 3 3 Telephone Caller 8 3 3 1 Outgoing call 9 3 3 2 Incoming call 9 4 Parameter programming 9 4 1 Programming from a telephone by DTMF 9 4 1 1 Entering programming mode 9 4 1 2 Parameter programming 9 4 2 Programming from a PC ID Manager program 10 5 Parameter description 10 5 1 Direct Dialling Memori...

Page 3: ...al time before dialling starts Ø Optional parameters for DTMF tones Recall and Pause duration Ø 3 default levels Ø Programming by remote control DTMF and by direct PC connection via USB cable available separately Ø Integrated heating of printed circuit PCB option Ø Permanent lighting through visiting cards option Ø Earthing outlet for better protection against static electricity Ø Switchable audib...

Page 4: ...ice connect the telephone wires into the terminal on the right side Using either a standard analogue phone line or an analogue extension on a PBX For the external power supply connect to the terminal 12V external power supply AC min 10V max 15V or DC min 12V max 18V The energy consumption of a connected electrical magnetic lock 0 5A 1 0A determines the load on the power supply If you activate the ...

Page 5: ...uld be suitable for most installations Change the trimmer position only when necessary The trimmer MIC is designed for microphone volume setting The trimmer SPK is designed for loudspeaker volume setting The volume settings are more than adequate for most situations Therefore we do not recommend setting the trimmer position more than The most suitable position is 1 3 from minimum amplification The...

Page 6: ...ting elements are located under the speaker front aluminium grille PC connector SlimDoorPhon e fixing screw hole Service switch Loudspeaker MIC setting of microphon e volume TRH setting of micropho ne activation SPK setting of speaker volume Heating activatio n 12V for relay light and heating Relay Telephone line connection Microphon e Buttons Hole for lead in cable ...

Page 7: ...ne is marked for easy cutting 2 4Final closing of ID Doorphone 2 4 1 Covering control elements 1 Push aluminium speaker cover back up see picture Take care when re covering the speaker The aluminium edge of the speaker may be gently pressed if required 2 4 2 Replacing name card panel 2 Push key into hole in speaker grille as far as possible see figure 2 3 Push name card panel upwards and push the ...

Page 8: ...hich is set in the unit parameter 47 Day night mode If the unit is in Day mode it will always dial the number set in parameter 1 In Night mode it will always dial the number set in parameter 2 The mode switchover is set in parameters 45 46 Two Group mode on the first press the number set in parameter 1 will be dialled By pressing of the same button twice or on detection of busy tone after trying t...

Page 9: ... Pick up line tone see Chapter 3 1 page8 Within 10 seconds dial xxxx where xxxx is the password for entry to programming and if OK the registration tone for programming mode will sound and afterwards the Programming tone is heard see Chapter 3 1 page 8 2 by SERVICE switch dial the unit in the same way as in 1 but when the SERVICE switch is connected the unit will automatically enter programming mo...

Page 10: ...ing 20 seconds 4 2Programming from a PC ID Manager program To setup the unit from a PC you will require a special USB tool cable available separately and must first install the USB driver and ID Manager software Refer to the CD for more details The unit must also be connected to the telephone line Procedure Connect the ID Doorphone to the line Connect the unit to the PC with the USB tool cable Run...

Page 11: ... close on command or password for ss period used for electrical locks gate opening etc m 2 button mode activated by button press e g external bell Paramet er Value Description Defaul t Exam 1 Exam 2 32 r hhhhhh External access code in DAY NIGHT mode 1212 1324 33 r hhhhhh External access code in DAY mode 2211 2211 34 r hhhhhh External access code in NIGHT mode 1122 1122 hhhhhh password for relay cl...

Page 12: ...iption Default Exam 1 Exam 2 41 v Dialling type 0 0 0 v dial type v 0 is DTMF tone dial v 1 is pulse dial Paramet er Value Description Default Exam 1 Exam 2 42 z Prolong call z button for call prolongation or 10 sec before Maximum Call Duration the unit will emit a tone Pressing this button will prolong the call Paramet er Value Description Default Exam 1 Exam 2 43 bb End call 55 55 55 bb command ...

Page 13: ...imum call duration 2 1 4 d maximum time in minutes for which a call may last This time can be extended during a call by dialling Prolong Call digit from telephone or Time setting is per table Paramet er Value Description Default Exam 1 Exam 2 53 w time between button presses 2 2 2 w max time sec between button presses range 1 9 relay closing if time between two next presses is bigger than w time t...

Page 14: ...m s 5 100m s 59 f Recall duration ms 1 100ms 1 100m s 1 100m s 50 p Pause duration ms 8 800ms 8 800m s 8 800m s t DTMF tone duration is determined by the formula entered number 5 x 10 tone duration ms range 1 0 i e 60 150ms m Space duration between DTMF tones is determined by the formula entered number 5 x 10 gap duration ms range 1 0 i e 60 150ms f Recall duration is determined by the formula ent...

Page 15: ...s tone z time of continous tone 1 1 2sec 7 3 3sec 2 1 6sec 8 3 6sec 3 2 0sec 9 3 9sec 4 2 3sec 0 4 2sec 5 2 6sec 4 6sec 6 3 0sec 5 0sec 5 5Presetting and Deleting Paramet er Value Description Default Exam 1 Exam 2 8 Default setting executes 8 1 Setting per exam 1 executes 8 2 Setting per exam 2 executes This setting does not influence 1 and 2 numbers stored in memory Paramet er Value Description D...

Page 16: ...tons ATTENTION This parameter can cause the unit to function incorrectly Paramet r Value Description Default Exam 1 Exam 2 6 z Acoustic signalling 3 and 9 3 and 9 3 and 9 In default the unit produces acoustic signals It can occasionally cause a problem of incorrect detection of tones by PBX By changing parameter z you can switch off this acoustic signalization The values are z 0 all signalling is ...

Page 17: ...tching 11 11 11 46 nn NIGHT MODE switching 10 10 10 47 e Dialling mode 1 1 0 51 q Number of rings before pick up 2 1 2 52 d Maximum call duration 2 1 4 53 w Time between button presses 2 2 2 54 z On hook time before new call 2 2 2 55 z Call start time 1 1 1 56 h Number of rings before hanging up or group mode switching 12 12 12 57 t DTMF tone duration ms 5 100ms 5 100ms 5 100ms 58 m Space duration...

Page 18: ...wered Minimum line voltage 18V line hang up Voltage on line while off hook VA characteristics 8V 12V I 20mA I 60 mA Leakage in hang up status 50uA U 60V Impedance of line termination 130R 820R paral 220n line answered Bandwidth 300Hz 3400 Hz 20 60mA Impedance of ringing 2Kohm 25 60 Hz Sensitivity of ringing detector min 10 25 V Pulse choice 40 60 ms Tone choice level 4 6 dB 20 60 mA Tone choice se...

Page 19: ...ay Gr 1 102 16 Number under button 3 Day Gr 1 103 16 Number under button 4 Day Gr 1 104 16 Number under button 1 Night Gr 2 201 16 Number under button 2 Night Gr 2 202 16 Number under button 3 Night Gr 2 203 16 Number under button 4 Night Gr 2 204 16 Relay mode m 1 2 31 1 External access code Day Night 32 6 External access code Day 33 6 External access code Night 34 6 Internal access code 35 2 Rel...