3.3.1

 

Outgoing call 

An “outgoing” call is a call from the unit (i.e. when a visitor presses a button). Once the 

visitor  has  pressed  a  button  a  telephone  will  ring.  On  answering  the  telephone,  you  will  be 
able to converse with the visitor. 10 seconds before the maximum call duration (

parameter 

52

)  the  unit  will  emit  a  tone  to  warn  that  the  call  will  end.  The  call  may  be  extended  by 

pressing the key as set in 

parameter 42

. A code may be dialled to close the relay (

parameter 

35

), releasing the lock. Hanging up the telephone will end the call, as will the busy tone from 

the PBX. 

3.3.2

 

Incoming call 

An  incoming  call  is  a  call  to  the  unit.  After  dialling  the  PBX  extension  number  to  which  the 
unit is connected, the unit will ring for the set number of rings (

parameter 51

), the unit will 

lift  up  and  it  is  possible  to  speak.  The  possibilities  are  the  same  as  with  outgoing  call 
(Chapter 3.3.1). It is also possible to switch between Day and Night service. 

 

If, within the first 10 seconds, the service password is entered, the unit will switch to 
programming mode and voice communication will cease. 

 

During an incoming call it is possible to restrict relay control 

(parameter 37).

 This can 

be useful in some special applications. 

 
 

4

 

Parameter programming 

4.1

 

Programming from a telephone by DTMF 

4.1.1

 

Entering programming mode 

The SlimDoorPhone may be set to programming mode in two ways: 

1.

 

by password

 – dial the unit‘s number 

(either extension number, if connected to a PBX or 

telephone  number,  if  connected  to  a  PSTN  line)

.  The  unit  will  answer  (you  will  hear  the 

Pick  up  line

  tone  –  see  Chapter  3.1  page8).  Within  10 seconds  dial 

#xxxx

,  where 

xxxx  is  the  password  for  entry  to  programming  and,  if  OK,  the  registration  tone  for 
programming mode will sound, and afterwards the 

Programming 

tone is heard (see 

Chapter 3.1 page 8). 

2.

 

by

 

"SERVICE"

 

switch

 – dial the unit in the same way as in 1, but when the SERVICE 

switch  is  connected,  the  unit  will  automatically  enter  programming  mode.  You  will 
hear  the  call  connection  confirmation  tone,  the  confirmation  tone  for  programming 
mode and afterwards the 

Programming

 tone is heard. (see Chapter 3.1 page 8). 

 

4.1.2

 

Parameter programming 

The  initial  state  for  programming  is  signalled  by  the  programming  confirmation  tone. 

The unit will always revert to this state after 5 seconds of inactivity, even if you have started 
to program a parameter. 

When  programming,  there  are  two  types  of  parameters.  The  majority  are  parameters 

with  a 

fixed  length

.  The  parameter  is  always  saved  immediately  and  is  confirmed  by 

Parameter Confirmation tone. Parameters 

with variable length

 (

parameters 1,2,32,33,34

are  saved  after  the  inactivity  period  expires  (5  sec).  However,  a  varaible  length  parameter 
will  be  saved  immediately  when  maximum  permitted  number  of  digits  is  reached.  For 
parameters 1 and 2 the maximum number of digits is 16, and for parameters 32,33,34 it is 
6. 

If,  during  programming,  you  enter  a  number  which  is  not  allowable,  then  the  unit 

immediately emits an 

error tone

. The parameter will not be recorded or changed, and the 

unit will return to its initial programming state and it will be possible to repeat the parameter 
setting or program another parameter. 

The unit stays inactive in programming mode for 34 seconds and will then automatically 

hang up. Every time a DTMF tone is dialled, this period is reset. Alternatively, parameter 9 
may also be selected to end programming mode. 

Summary of Contents for SlimDoorPhone 1 button

Page 1: ...om France 11 rue du Soleil Levant 92140 CLAMART Copyright 2012 Linkcom Tous droits réservés 1 Slim Door Phone 1 2 or 4 buttons Manuel V2 2 find the latest version of the manual and firmware at www linkcom fr ...

Page 2: ...g name card panel 7 3 SlimDoorPhone Services 8 3 1 Signalling Overview 8 3 2 Visitor at the door 8 3 3 Telephone Caller 8 3 3 1 Outgoing call 9 3 3 2 Incoming call 9 4 Parameter programming 9 4 1 Programming from a telephone by DTMF 9 4 1 1 Entering programming mode 9 4 1 2 Parameter programming 9 4 2 Programming from a PC ID Manager program 10 5 Parameter description 10 5 1 Direct Dialling Memori...

Page 3: ...al time before dialling starts Ø Optional parameters for DTMF tones Recall and Pause duration Ø 3 default levels Ø Programming by remote control DTMF and by direct PC connection via USB cable available separately Ø Integrated heating of printed circuit PCB option Ø Permanent lighting through visiting cards option Ø Earthing outlet for better protection against static electricity Ø Switchable audib...

Page 4: ...ice connect the telephone wires into the terminal on the right side Using either a standard analogue phone line or an analogue extension on a PBX For the external power supply connect to the terminal 12V external power supply AC min 10V max 15V or DC min 12V max 18V The energy consumption of a connected electrical magnetic lock 0 5A 1 0A determines the load on the power supply If you activate the ...

Page 5: ...uld be suitable for most installations Change the trimmer position only when necessary The trimmer MIC is designed for microphone volume setting The trimmer SPK is designed for loudspeaker volume setting The volume settings are more than adequate for most situations Therefore we do not recommend setting the trimmer position more than The most suitable position is 1 3 from minimum amplification The...

Page 6: ...ting elements are located under the speaker front aluminium grille PC connector SlimDoorPhon e fixing screw hole Service switch Loudspeaker MIC setting of microphon e volume TRH setting of micropho ne activation SPK setting of speaker volume Heating activatio n 12V for relay light and heating Relay Telephone line connection Microphon e Buttons Hole for lead in cable ...

Page 7: ...ne is marked for easy cutting 2 4Final closing of ID Doorphone 2 4 1 Covering control elements 1 Push aluminium speaker cover back up see picture Take care when re covering the speaker The aluminium edge of the speaker may be gently pressed if required 2 4 2 Replacing name card panel 2 Push key into hole in speaker grille as far as possible see figure 2 3 Push name card panel upwards and push the ...

Page 8: ...hich is set in the unit parameter 47 Day night mode If the unit is in Day mode it will always dial the number set in parameter 1 In Night mode it will always dial the number set in parameter 2 The mode switchover is set in parameters 45 46 Two Group mode on the first press the number set in parameter 1 will be dialled By pressing of the same button twice or on detection of busy tone after trying t...

Page 9: ... Pick up line tone see Chapter 3 1 page8 Within 10 seconds dial xxxx where xxxx is the password for entry to programming and if OK the registration tone for programming mode will sound and afterwards the Programming tone is heard see Chapter 3 1 page 8 2 by SERVICE switch dial the unit in the same way as in 1 but when the SERVICE switch is connected the unit will automatically enter programming mo...

Page 10: ...ing 20 seconds 4 2Programming from a PC ID Manager program To setup the unit from a PC you will require a special USB tool cable available separately and must first install the USB driver and ID Manager software Refer to the CD for more details The unit must also be connected to the telephone line Procedure Connect the ID Doorphone to the line Connect the unit to the PC with the USB tool cable Run...

Page 11: ... close on command or password for ss period used for electrical locks gate opening etc m 2 button mode activated by button press e g external bell Paramet er Value Description Defaul t Exam 1 Exam 2 32 r hhhhhh External access code in DAY NIGHT mode 1212 1324 33 r hhhhhh External access code in DAY mode 2211 2211 34 r hhhhhh External access code in NIGHT mode 1122 1122 hhhhhh password for relay cl...

Page 12: ...iption Default Exam 1 Exam 2 41 v Dialling type 0 0 0 v dial type v 0 is DTMF tone dial v 1 is pulse dial Paramet er Value Description Default Exam 1 Exam 2 42 z Prolong call z button for call prolongation or 10 sec before Maximum Call Duration the unit will emit a tone Pressing this button will prolong the call Paramet er Value Description Default Exam 1 Exam 2 43 bb End call 55 55 55 bb command ...

Page 13: ...imum call duration 2 1 4 d maximum time in minutes for which a call may last This time can be extended during a call by dialling Prolong Call digit from telephone or Time setting is per table Paramet er Value Description Default Exam 1 Exam 2 53 w time between button presses 2 2 2 w max time sec between button presses range 1 9 relay closing if time between two next presses is bigger than w time t...

Page 14: ...m s 5 100m s 59 f Recall duration ms 1 100ms 1 100m s 1 100m s 50 p Pause duration ms 8 800ms 8 800m s 8 800m s t DTMF tone duration is determined by the formula entered number 5 x 10 tone duration ms range 1 0 i e 60 150ms m Space duration between DTMF tones is determined by the formula entered number 5 x 10 gap duration ms range 1 0 i e 60 150ms f Recall duration is determined by the formula ent...

Page 15: ...s tone z time of continous tone 1 1 2sec 7 3 3sec 2 1 6sec 8 3 6sec 3 2 0sec 9 3 9sec 4 2 3sec 0 4 2sec 5 2 6sec 4 6sec 6 3 0sec 5 0sec 5 5Presetting and Deleting Paramet er Value Description Default Exam 1 Exam 2 8 Default setting executes 8 1 Setting per exam 1 executes 8 2 Setting per exam 2 executes This setting does not influence 1 and 2 numbers stored in memory Paramet er Value Description D...

Page 16: ...tons ATTENTION This parameter can cause the unit to function incorrectly Paramet r Value Description Default Exam 1 Exam 2 6 z Acoustic signalling 3 and 9 3 and 9 3 and 9 In default the unit produces acoustic signals It can occasionally cause a problem of incorrect detection of tones by PBX By changing parameter z you can switch off this acoustic signalization The values are z 0 all signalling is ...

Page 17: ...tching 11 11 11 46 nn NIGHT MODE switching 10 10 10 47 e Dialling mode 1 1 0 51 q Number of rings before pick up 2 1 2 52 d Maximum call duration 2 1 4 53 w Time between button presses 2 2 2 54 z On hook time before new call 2 2 2 55 z Call start time 1 1 1 56 h Number of rings before hanging up or group mode switching 12 12 12 57 t DTMF tone duration ms 5 100ms 5 100ms 5 100ms 58 m Space duration...

Page 18: ...wered Minimum line voltage 18V line hang up Voltage on line while off hook VA characteristics 8V 12V I 20mA I 60 mA Leakage in hang up status 50uA U 60V Impedance of line termination 130R 820R paral 220n line answered Bandwidth 300Hz 3400 Hz 20 60mA Impedance of ringing 2Kohm 25 60 Hz Sensitivity of ringing detector min 10 25 V Pulse choice 40 60 ms Tone choice level 4 6 dB 20 60 mA Tone choice se...

Page 19: ...ay Gr 1 102 16 Number under button 3 Day Gr 1 103 16 Number under button 4 Day Gr 1 104 16 Number under button 1 Night Gr 2 201 16 Number under button 2 Night Gr 2 202 16 Number under button 3 Night Gr 2 203 16 Number under button 4 Night Gr 2 204 16 Relay mode m 1 2 31 1 External access code Day Night 32 6 External access code Day 33 6 External access code Night 34 6 Internal access code 35 2 Rel...

Page 20: ...Linkcom France 11 rue du Soleil Levant 92140 CLAMART Copyright 2012 Linkcom Tous droits réservés 20 Gap between DTMF tones n 5 x10 58 ms 1 Recall duration nx100 59 ms 1 Pause duration nx100 50 ms 1 ...

Page 21: ...Linkcom France 11 rue du Soleil Levant 92140 CLAMART Copyright 2012 Linkcom Tous droits réservés 21 8 Drilling master board ...

Page 22: ......

Reviews: