Linkcom France
11 rue du Soleil Levant 92140 CLAMART
Copyright © 2012 – Linkcom – Tous droits réservés
4
2.1.2
Uncover control elements
4.
Push the aluminium speaker grille down (see figure – 4).
2.1.3
Wiring and wall mounting
5.
Use the wall mounting template at the end of the manual
to mark the position for the screw holes and cable
connection on the mounting surface. Drill the holes.
6.
Feed the cable (analogue line, power supply, lock – see
figure - 6) through the cable hole.
Fix the panel to the wall using the screws and rawlplugs
supplied.
Note:
Some materials such as metal and wood may
require special screw types.
To power the unit for voice, connect the telephone
wires into the terminal (on the right side). Using
either a standard analogue phone line or an
analogue extension on a PBX.
For the external power supply, connect to the terminal "
12V
" external power supply AC
min. 10V / max. 15V or DC min. 12V / max. 18V.
The energy consumption of a connected electrical (magnetic) lock (0,5A – 1,0A)
determines the load on the power supply. If you activate the heating feature the PCB
current will climb to about 150mA. We recommend power supply AC 12V/1A.
The wiring of relay contacts is explained in the next picture. The symbol "
NO
" means
contact normally open, "
COM
" means sharing output
(central) and "
NC
" means contact normally closed. The relay contact is isolated from the
other circuits on the board. For the variants of lock connection see the picture below.
Power
supply
lock
Telephon
e line
Summary of Contents for SlimDoorPhone 1 button